Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case.

[1]  J. Ravenel The Essential Physics of Medical Imaging, 2nd ed. , 2003 .

[2]  W. Huda,et al.  Estimation of mean organ doses in diagnostic radiology from Rando phantom measurements. , 1984, Health physics.

[3]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[4]  J. Bushberg The Essential Physics of Medical Imaging , 2001 .

[5]  J. Zoetelief,et al.  Recommendations for patient dosimetry in diagnostic radiology using TLD. Topical report , 2000 .

[6]  P. Serruys,et al.  Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. , 2002, The American journal of cardiology.

[7]  K. Kopecky,et al.  Multi-slice CT spirals past single-slice CT in diagnostic efficacy. , 1999, Diagnostic imaging.

[8]  M D Phillips,et al.  Multisection CT: scanning techniques and clinical applications. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[9]  R. Bale,et al.  [Radiation exposure in single slice and multi-slice spiral CT (a phantom study)]. , 2001, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[10]  R A Kruger,et al.  Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. , 1996, Medical physics.

[11]  H. Nagel,et al.  CT-Expositionspraxis in der Bundesrepublik Deutschland , 2001 .

[12]  W A Kalender,et al.  System performance of multislice spiral computed tomography. , 2000, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[13]  T. Vogl,et al.  Colonography: current status, research directions and challenges. Update 2002 , 2002, European Radiology.

[14]  Richard L Morin,et al.  Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart. , 2002, Mayo Clinic proceedings.

[15]  J. K. Smith,et al.  Multidetector-array CT: once again, technology creates new opportunities. , 1998, Radiology.

[16]  C D Claussen,et al.  Virtual coronary angioscopy using multislice computed tomography , 2002, Heart.

[17]  Claus D. Claussen,et al.  Multidetector helical CT of the liver for tumor detection and characterization , 2002, European Radiology.

[18]  S Schaller,et al.  Subsecond multi-slice computed tomography: basics and applications. , 1999, European journal of radiology.

[19]  W. Lees,et al.  Multi-slice technology in computed tomography. , 2001, Clinical radiology.

[20]  H. Nagel,et al.  CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT , 2002 .

[21]  T. Hagen,et al.  Patient doses from standard and spiral CT of the head using a fast twin-beam system. , 1997, The British journal of radiology.

[22]  D W McRobbie,et al.  Radiation Exposure in Computed Tomography: Fundamentals, Influencing Parameters, Dose Assessment, Optimisation, Scanner Data, Terminology , 2001 .

[23]  M. Rieger,et al.  Untersuchungen zur Strahlenexposition bei der Einzelschicht- und Mehrschicht-Spiral-CT (eine Phantom-Studie) , 2001 .

[24]  M. Reiser,et al.  Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. , 2002, Radiology.

[25]  G. Rubin,et al.  Data explosion: the challenge of multidetector-row CT. , 2000, European journal of radiology.

[26]  W. Kalender,et al.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.

[27]  A. Bolsi,et al.  [Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels]. , 2001, La Radiologia medica.

[28]  Nations United sources and effects of ionizing radiation , 2000 .

[29]  C. White,et al.  Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. , 2001, The American journal of cardiology.

[30]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[31]  W A Kalender,et al.  Technical advances in multi-slice spiral CT. , 2000, European journal of radiology.