Analysis of Stator Internal Phase-to-Phase Short Circuit in the 12-Phase Synchronous Generator With Rectifier-Load System

The 12-phase synchronous generator–rectifier system is widely used in mobile platforms that require high system security. In the system, the stator internal short circuit is a kind of common fault that may compromise the security of the generator. This paper gives detailed analysis on the internal phase-to-phase short-circuit faults, including the faults within the same group of Y-connected phases and those between different groups of Y-connected phases in the 12-phase system. A multiloop mathematical model is built to calculate all the voltages and currents when the faults occur in the system. In the model, the additional short-circuit loop between different phases, as well as the fault effects on both the air-gap magnetic field and the circuit topology of the system, are taken into account. Then a series of fault experiments are carried out on a 12-phase model machine. In view of the good agreement of experiment and simulation results, the effectiveness of the mathematical model and the simulation method is confirmed. Finally, the electric characteristics of the internal phase-to-phase short-circuit faults are summarized, and the fault mechanism is revealed.

[1]  Emil Levi,et al.  Multiphase Electric Machines for Variable-Speed Applications , 2008, IEEE Transactions on Industrial Electronics.

[2]  D. Howe,et al.  Transient behaviour of salient-pole synchronous machines with internal stator winding faults , 2002 .

[3]  S. Castellan,et al.  Analysis of asymmetrical short circuits downstream of 12 pulse diode rectifier fed by double three phase synchronous machines , 2014 .

[4]  S. D. Sudhoff,et al.  Analysis and average-value modeling of an inductorless synchronous machine load commutated converter system , 1999 .

[5]  Ming Fang,et al.  Transient DC Side Short Circuit Currents of 12-phase generator-rectifier system , 2008, 2008 International Conference on Electrical Machines and Systems.

[6]  Longya Xu,et al.  A study of armature winding internal faults for turbogenerators , 2002 .

[7]  H. Fujita,et al.  An analytical method for calculating harmonic currents of a three-phase diode-bridge rectifier with DC filter , 1994 .

[8]  Keith Corzine,et al.  Transient and dynamic average-value modeling of synchronous machine fed load-commutated converters , 1996 .

[9]  M Maarten Steinbuch,et al.  Dynamic modeling of a generator/rectifier system , 1992 .

[10]  Judith Apsley,et al.  Open-circuit fault analysis of diode rectified multiphase synchronous generators for DC aircraft power systems , 2013, 2013 International Electric Machines & Drives Conference.

[11]  F.C. Trutt,et al.  Detection of A-C machine winding deterioration using electrically excited vibrations , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).