Accuracy Evaluation of Ultrawideband Time Domain Systems for Microwave Imaging

We perform a theoretical analysis of the measurement accuracy of ultrawideband time domain systems. The theory is tested on a specific ultrawideband system and the analytical estimates of measurement uncertainty are in good agreements with those obtained by means of simulations. The influence of the antennas and propagation effects on the measurement accuracy of time domain near field microwave imaging systems is discussed. As an interesting application, the required measurement accuracy for a breast cancer detection system is estimated by studying the effect of noise on the image reconstructions. The results suggest that the effects of measurement errors on the reconstructed images are small when the amplitude uncertainty and phase uncertainty of measured data are less than 1.5 dB and 15 degrees, respectively.

[1]  K. Paulsen,et al.  Microwave image reconstruction of tissue property dispersion characteristics utilizing multiple-frequency information , 2004, IEEE Transactions on Microwave Theory and Techniques.

[2]  L. Jofre,et al.  Active microwave imaging of inhomogeneous bodies , 1985 .

[3]  Robert H. Svenson,et al.  Three-dimensional microwave tomography: experimental imaging of phantoms and biological objects , 2000 .

[4]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[5]  W. Gans The Measurement and Deconvolution of Time Jitter in Equivalent-Time Waveform Samplers , 1983, IEEE Transactions on Instrumentation and Measurement.

[6]  L.P. Ligthart,et al.  UWB Array-Based Sensor for Near-Field Imaging , 2007, IEEE Transactions on Microwave Theory and Techniques.

[7]  A. Preece,et al.  Radar-Based Breast Cancer Detection Using a Hemispherical Antenna Array—Experimental Results , 2009, IEEE Transactions on Antennas and Propagation.

[8]  Marc Acheroy,et al.  Time-domain simulation and characterisation of TEM horns using a normalised impulse response , 2000 .

[9]  A.E. Fathy,et al.  Development and Implementation of Ultra-Wideband See-Through-Wall Imaging System Based on Sampling Oscilloscope , 2008, IEEE Antennas and Wireless Propagation Letters.

[10]  Bernard Widrow,et al.  Quantization Noise: Roundoff Error in Digital Computation, Signal Processing, Control, and Communications , 2008 .

[11]  T. S. ENGLAND,et al.  Dielectric Properties of the Human Body in the Microwave Region of the Spectrum , 1949, Nature.

[12]  George W. Stimson,et al.  Introduction to Airborne Radar , 1983 .

[13]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[14]  Takashi Takenaka,et al.  Two-Dimensional Time-Domain Inverse Scattering for Quantitative Analysis of Breast Composition , 2008, IEEE Transactions on Biomedical Engineering.

[15]  Paul M. Meaney,et al.  A clinical prototype for active microwave imaging of the breast , 2000 .

[16]  Raphael Kastner,et al.  Antenna characterization in the time domain , 1997 .

[17]  G. Vecchi,et al.  Experimental Tests of Microwave Breast Cancer Detection on Phantoms , 2009, IEEE Transactions on Antennas and Propagation.

[18]  Andreas Fhager,et al.  Reconstruction Quality and Spectral Content of an Electromagnetic Time-Domain Inversion Algorithm , 2006, IEEE Transactions on Biomedical Engineering.

[19]  Elise C. Fear,et al.  Microwave detection of breast cancer , 2000 .

[20]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[21]  K. Paulsen,et al.  Near-field microwave imaging of biologically-based materials using a monopole transceiver system , 1998 .

[22]  W.L. Gans Calibration and error analysis of a picosecond pulse waveform measurement system at NBS , 1986, Proceedings of the IEEE.

[23]  Cheong Boon Soh,et al.  UWB Microwave Imaging for Breast Cancer Detection --- Experiments with Heterogeneous Breast Phantoms , 2011 .

[24]  Paul M. Meaney,et al.  Enhancing breast tumor detection with near-field imaging , 2002 .

[25]  William L. Gans,et al.  Dynamic calibration of waveform recorders and oscilloscopes using pulse standards , 1990 .

[26]  Weng Cho Chew,et al.  Time-domain ultra-wideband microwave imaging radar system , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[27]  David J. Edwards,et al.  Ultra-wideband : antennas and propagation for communications, radar and imaging , 2006 .

[28]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[29]  Xu Li,et al.  Microwave imaging via space-time beamforming for early detection of breast cancer , 2002, 2002 IEEE International Conference on Acoustics, Speech, and Signal Processing.

[30]  Andreas Fhager,et al.  Study on the sensitivity of image reconstruction to the measurement uncertainty in microwave tomography , 2010, Proceedings of the Fourth European Conference on Antennas and Propagation.

[31]  W. Chew,et al.  A frequency-hopping approach for microwave imaging of large inhomogeneous bodies , 1995, IEEE Antennas and Propagation Society International Symposium. 1995 Digest.