Amine reactive dyes: an effective tool to discriminate live and dead cells in polychromatic flow cytometry.

Membrane-damaged cells caused by either mechanical trauma or through normal biological processes can produce artifacts in immunophenotyping analysis by flow cytometry. Dead cells can nonspecifically bind monoclonal antibody conjugates, potentially leading to erroneous conclusions, particularly when cell frequencies are low. To date, DNA intercalating dyes (Ethidium monoazaide (EMA), Propidium Iodide, 7AAD, etc.) or Annexin V have been commonly used to exclude dead cells; however, each suffer from technical problems. The first issue with such dyes is the dependence on a consistent dead cell source for fluorescence compensation. Another major issue is the stability of the staining; except for EMA, fixation and permeablization used for intracellular staining procedures can cause loss of fluorescence. EMA requires a UV exposure to covalently bond to DNA; while this dye is effective and is not affected by intracellular treatments it is weakly fluorescent. Here we report on the optimization of a new class of viability dyes, the amine reactive viability dyes (ViD) as a dead cell exclusion marker. The inclusion of ViD into the staining panel was found to be simple, reproducible and can have a significant benefit on the accuracy of identifying appropriate cell populations. We show the fluorescence of cells stained with these dyes correlates with traditional dead cell discriminating markers, even after fixation and permeabilization. Amine reactive viability dyes are a powerful tool for fluorescence immunophenotyping experiments.

[1]  Locksley E. McGann,et al.  Light scattering and cell volumes in osmotically stressed and frozen-thawed cells☆☆☆ , 1986 .

[2]  M. Altfeld,et al.  Standardization of cytokine flow cytometry assays , 2005, BMC Immunology.

[3]  J. Giorgi,et al.  Flow cytometric analysis of live cell proliferation and phenotype in populations with low viability. , 1999, Cytometry.

[4]  P. Chattopadhyay,et al.  Seventeen-colour flow cytometry: unravelling the immune system , 2004, Nature Reviews Immunology.

[5]  P. Costantino,et al.  Enumeration of viable Candida albicans blastospores using tetrabromofluorescein (eosin Y) and flow cytometry. , 1995, Cytometry.

[6]  D. Bourel,et al.  Distribution of radiolabelled monoclonal antibody Po66 after intravenous injection into nude mice bearing human lung cancer grafts , 2005, Cancer Immunology, Immunotherapy.

[7]  C. Stewart,et al.  Use of a photolabeling technique to identify nonviable cells in fixed homologous or heterologous cell populations. , 1991, Cytometry.

[8]  M. Loken,et al.  Two color light scattering identifies physical differences between lymphocyte subpopulations. , 1982, Cytometry.

[9]  R. G. Clarke,et al.  Improved detection of bacteria by flow cytometry using a combination of antibody and viability markers , 1998, Journal of applied microbiology.

[10]  W. Bolton,et al.  Comparison of cell viability probes compatible with fixation and permeabilization for combined surface and intracellular staining in flow cytometry. , 1995, Cytometry.