Modelling and gait evaluation of asymmetrical-keel foot prosthesis

The paper documents a new concept in prosthetic foot design. It is based on the capacity of a flexible keel to allow a greater medio-lateral function than previously available. the heel has a complex curvature consisting of a medially concave shape that joins the mid-foot. There a hump acting as a leaf-spring ends at the metatarsal break, with an inwardly curved toe extremity. These curvatures contribute to increased medio-lateral control at heel-strike and propulsion for weight transfer and push-off. Results from finite-element modelling indicate that the asymmetrically shaped keel is at least twice as active in storing energy compared with a completely symmetrical one. A preliminary gait study is carried out for a 24-year-old below-knee amputee fitted with the new design, the SPACE foot and a dynamic elastic response foot with a symmetrical keel. With the SPACE foot, there is a 14% increase in walking speed combined with a reduction in the phasic asymmetries. The absolute difference between the initial and terminal double support is 1.4% for the asymmetrical keel design compared with 4.4% for the symmetrical keel foot prosthesis. The peak ankle power generation burst indicates that the SPACE foot behaves as a dynamic elastic response foot.

[1]  Energy-storing prosthetic feet. , 1989, Archives of physical medicine and rehabilitation.

[2]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .

[3]  B J McFadyen,et al.  Running gait impulse asymmetries in below-knee amputees , 1992, Prosthetics and orthotics international.

[4]  S. Simon,et al.  Role of the posterior calf muscles in normal gait. , 1978, The Journal of bone and joint surgery. American volume.

[5]  B J McFadyen,et al.  Comparison of gait between young adults fitted with the space foot and nondisabled persons. , 1993, Archives of physical medicine and rehabilitation.

[6]  D. Winter,et al.  Biomechanics of below-knee amputee gait. , 1988, Journal of biomechanics.

[7]  Genaro Tolentino Marzan,et al.  Rational Design for Close-Range Photogrammetry , 1976 .

[8]  J Perry,et al.  Below-knee amputee gait with dynamic elastic response prosthetic feet: a pilot study. , 1990, Journal of rehabilitation research and development.

[9]  J. Czerniecki,et al.  BIOMECHANICAL ANALYSIS OF THE INFLUENCE OF PROSTHETIC FEET ON BELOW-KNEE AMPUTEE WALKING , 1991, American journal of physical medicine & rehabilitation.