Broadband spectral measurements of diffuse optical properties by an integrating sphere instrument at the National Institute of Standards and Technology

Diffuse materials that approximate the optical properties of human tissue are commonly used as phantoms. In order to use the phantoms in a manner that provides consistent results relative to independent measurements, the optical properties need to be tied to a physics based scale. Such a scale is needed for volume scattering of diffuse materials and this is currently being addressed by the development of a sphere based optical scattering reference instrument at the National Institute of Standards and Technology (NIST). Previous work towards that goal was constrained to the use of several laser lines at discrete wavelengths. Current work has expanded the spectral range for contiguous coverage. Here we report measurement results of the optical properties of solid phantoms, using two different base materials, acquired using NISTs diffuse optical properties reference instrument with visible or near infrared broadband illumination. The measurements of diffuse hemispherical reflectance and transmittance are analyzed using a custom inversion algorithm of the adding-doubling routine, and the expanded uncertainties on the results are provided. The broadband diffuse optical properties measured with the improved system agree to within the estimated uncertainty of the discrete measurements from two other institutes using alternative methods. This work expands the capabilities of the facility and can provide services for a wider range of applications.

[1]  M. Kacprzak,et al.  Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink. , 2014, Biomedical optics express.

[2]  Paul Lemaillet,et al.  National Institute of Standards and Technology measurement service of the optical properties of biomedical phantoms: current status , 2016, SPIE BiOS.

[3]  Paul Lemaillet,et al.  Goniometric and hemispherical reflectance and transmittance measurements of fused silica diffusers , 2016, Optical Engineering + Applications.

[4]  Dirk Grosenick,et al.  Time-resolved transmittance: a comparison of the diffusion model approach with Monte Carlo simulations , 2015, European Conference on Biomedical Optics.

[5]  Scott A Prahl,et al.  Preparation and characterization of polyurethane optical phantoms. , 2006, Journal of biomedical optics.

[6]  Jean-Pierre Bouchard,et al.  Development of traceable measurement of the diffuse optical properties of solid reference standards for biomedical optics at National Institute of Standards and Technology. , 2015, Applied optics.

[7]  Isabelle Noiseux,et al.  Reference optical phantoms for diffuse optical spectroscopy. Part 1--Error analysis of a time resolved transmittance characterization method. , 2010, Optics express.

[8]  Paul Lemaillet,et al.  Double-integrating-sphere system at the National Institute of Standards and Technology in support of measurement standards for the determination of optical properties of tissue-mimicking phantoms , 2015, Journal of biomedical optics.

[9]  A. Welch,et al.  Determining the optical properties of turbid mediaby using the adding-doubling method. , 1993, Applied optics.