A Gravitational Search Algorithm Based Static VAR Compensator Switching Function Optimization Technique for Minimum Harmonic Injection

Abstract Switching function optimization for minimum source harmonic injection for a static VAR compensator is presented. The static VAR compensator is configured with a fixed capacitor and insulated-gate bipolar transistor controlled reactor. The switching function is optimized for minimum source harmonic injection considering the desired fundamental voltage across load terminals. A gravitational search algorithm is employed for this purpose. It is observed that the proposed switching scheme with two different switching angles per half-cycle provides lower source harmonic injection compared to conventional switching, hence improving the source current harmonics. The switching angles are computed off-line using the gravitational search algorithm for varying modulation indices considering the minimum total harmonic distortion of the reactor voltage. The switching angles are stored in a processor as a function of the modulation index for on-line application using a piecewise mixed model approximation technique for low memory usage. It is observed that the proposed switching improves the source current total harmonic distortion on an average of 4 to 5% over most of the operating range compared to conventional switching without optimization. Various simulation and experimental results are presented on different loads to validate the proposed concept.

[1]  Luiz A. C. Lopes,et al.  An efficient switched-reactor-based static VAr compensator , 1994 .

[2]  Laszlo Gyugyi,et al.  Power electronics in electric utilities: static VAR compensators , 1988, Proc. IEEE.

[3]  Robert H. Lasseter,et al.  Harmonic Interactions in Thyristor Controlled Reactor Circuits , 1989, IEEE Power Engineering Review.

[4]  An Luo,et al.  Power Electronic Hybrid System for Load Balancing Compensation and Frequency-Selective Harmonic Suppression , 2012, IEEE Transactions on Industrial Electronics.

[5]  Peter Wood,et al.  Switching Power Converters , 1981 .

[6]  Provas Kumar Roy,et al.  Solution of unit commitment problem using gravitational search algorithm , 2013 .

[7]  L. Gyugyi,et al.  Static power frequency changers: Theory, performance, and application , 1976 .

[8]  L. Gyugyi,et al.  Principles and Applications of Static, Thyristor-Controlled Shunt Compensators , 1978, IEEE Transactions on Power Apparatus and Systems.

[9]  A. Lopez,et al.  Power-quality improvement in reactive power control using FC-TCR circuits , 2002, IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.

[10]  R. Mahanty Modified static VAR compensator using a large value AC capacitor , 2010 .

[11]  R. Ray,et al.  Harmonics elimination in a multilevel inverter using the particle swarm optimisation technique , 2009 .

[12]  Debashis Chatterjee A Novel Magnetizing-Curve Identification and Computer Storage Technique for Induction Machines Suitable for Online Application , 2011, IEEE Transactions on Industrial Electronics.

[13]  Xi-Fan Wang,et al.  HVDC and FACTS , 2008 .

[14]  Harmonic Domain Periodic Steady-State Modeling of Power Electronics Apparatus: SVC and TCSC , 2002, IEEE Power Engineering Review.

[15]  L.A.S. Pilotto,et al.  Thyristor-Controlled Reactors Nonlinear and Linear Dynamic Analytical Models , 2008, IEEE Transactions on Power Delivery.

[16]  D.B. Kulkarni,et al.  ANN based SVC switching at distribution level for minimal injected harmonics , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[17]  R. Mahanty Large value AC capacitor for harmonic filtering and reactive power compensation , 2008 .

[18]  L. Gerin-Lajoie,et al.  Basic aspects of applying SVC's to series-compensated AC transmission lines , 1990 .

[19]  An Luo,et al.  Combined System for Harmonic Suppression and Reactive Power Compensation , 2009, IEEE Transactions on Industrial Electronics.

[20]  Serhat Duman,et al.  Optimal reactive power dispatch using a gravitational search algorithm , 2012 .

[21]  S. Chirarattananon,et al.  Harmonic minimizing neural network SVC controller for compensating unbalanced fluctuating loads , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[22]  H. W. Hill,et al.  A new control strategy for static VAr compensators for minimum harmonic injection , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[23]  D. Thukaram,et al.  Harmonic minimization in the operation of static VAR compensators for unbalanced reactive power compensation , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[24]  Marouf Pirouti,et al.  Neural network-based Load Balancing and Reactive Power Control by Static VAR Compensator , 2009 .

[25]  Hossein Nezamabadi-pour,et al.  GSA: A Gravitational Search Algorithm , 2009, Inf. Sci..