Direct-conversion 50 μm pixel-pitch detector for digital mammography using amorphous selenium as a photoconductive switching layer for signal charge readout

A novel mammography detector with dual amorphous-Selenium (α-Se) layer has been developed that employs photoinduced discharge in its readout procedure. The detector consists of a bias electrode, a thick α-Se layer for x-ray-to-electron conversion, an electron-trapping layer (ETL), a thin α-Se layer for the photoinduced discharge, alternately arranged transparent and opaque stripe electrodes, and a linear optical source for readout. The detector directly converts x-rays into electrons to accumulate the electrons in ETL. When photoinduced discharge arises on the transparent electrodes through readout light irradiation, an accumulated electron image is transferred to the transparent electrodes and detected as signals at charge amplifiers, which we call 'Photoconductive Switching' readout. Readout efficiency and image readout speed have been improved enough to be used as a practical level by the adoption of the alternatelyarranged stripe electrodes. Furthermore, such a simple stripe-electrode structure accomplishes low electrical-noise readout and easy fabrication of fine-pitch pixels. A prototype 50 ìm pixel-pitch detector with the 18×24 cm imaging area has been prepared, which shows high DQE performances more than 64, 48, and 28% at 1, 4, and 7 lp/mm, respectively, not only in the usual dose range of around 100 μGy but at the low dose of 32 μGy. The 'Photoconductive Switching' readout mechanism makes it possible to realize the high DQE and the finest resolution of 50 μm in the direct-conversion detectors for full-field digital mammography.

[1]  Kyle J Myers,et al.  Lubberts effect in columnar phosphors. , 2004, Medical physics.

[2]  Yi Wang,et al.  Investigation of strategies to achieve optimal DQE performance from indirect-detection active-matrix flat-panel imagers (AMFPIs) through novel pixel amplification architectures (Invited Paper) , 2005, SPIE Medical Imaging.

[3]  Zhenxue Jing,et al.  Characterization of a full-field digital mammography detector based on direct x-ray conversion in selenium , 2002, SPIE Medical Imaging.

[4]  John A. Rowlands,et al.  Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography , 2001, SPIE Medical Imaging.

[5]  H de Monts,et al.  A new photoconductor imaging system for digital radiography. , 1989, Medical physics.

[6]  J. L. Hartke,et al.  Electronic States in Vitreous Selenium , 1965 .

[7]  John A Rowlands,et al.  Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system. , 2008, Medical physics.

[8]  I. Cunningham Applied Linear-Systems Theory , 2000 .

[9]  Douglas Albagli,et al.  Performance of advanced a-Si/CsI-based flat-panel x-ray detectors for mammography , 2003, SPIE Medical Imaging.

[10]  A Workman,et al.  A comparison of the imaging properties of CCD-based devices used for small field digital mammography. , 2002, Physics in medicine and biology.

[11]  Marcelo Mulato,et al.  Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays , 2001 .

[12]  Qihua Zhao,et al.  Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography. , 2007, Medical physics.

[13]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: photoinduced discharge (PID) readout for digital general radiography. , 1995, Medical physics.

[14]  F R Verdun,et al.  A comparison of the performance of digital mammography systems. , 2007, Medical physics.

[15]  I A Cunningham,et al.  Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors. , 2006, Medical physics.

[16]  Mehmet A. Baysal,et al.  A new CMOS-based digital imaging detector for applications in mammography , 2005, SPIE Optics + Photonics.