Test-retest reliability of three-dimensional kinematics using an electromagnetic tracking system during single-leg squat and stepping maneuver.

The electromagnetic tracking system (ETS) has been used to analyze three-dimensional (3D) lower limb kinematics. The single-leg squat and stepping maneuver are useful tasks to evaluate lower extremity alignment in a clinical setting. The purpose of this study was to evaluate the test-retest reliability of trunk, pelvis, hip, and knee 3D kinematics using an ETS during single-leg squat and stepping maneuver and compare 3D kinematics between tasks. Twenty healthy volunteers (10 males and 10 females) completed two test sessions 3-5 days apart. Three-dimensional kinematics using an ETS was assessed during single-leg squat and stepping maneuver. Overall, intrarater-intrasession reliability (ICCs=0.83-1.00) and intersession reliabilities (ICCs=0.82-0.97) were high during single-leg squat and stepping maneuver. The intrasession minimal detectable change (MDC) ranged from 1.3° for the knee frontal plane range of motion for single-leg squat to 6.2° for the pelvic transverse range of motion for the stepping maneuver. Intersession MDC values ranged from 1.2° for the ipsilateral trunk lean for the single-leg squat to 8.3° for hip flexion for the stepping maneuver. Healthy participants exhibited greater anterior pelvic tilt, more hip flexion, and less contralateral pelvis forward excursion (p<0.05) during single-leg squat compared with the stepping maneuver. These findings suggest that the 3D kinematics of the trunk, pelvis, hip, and knee using an ETS is reliable during single-leg squat and the stepping maneuver. Minimal detectable change values were low during the evaluated activities. Intertask comparisons revealed differences in hip and pelvis kinematics.

[1]  Jonathan P. Braman,et al.  Shoulder kinematics during the wall push-up plus exercise. , 2010, Journal of shoulder and elbow surgery.

[2]  Darin A Padua,et al.  Influence of trunk flexion on hip and knee joint kinematics during a controlled drop landing. , 2008, Clinical biomechanics.

[3]  Gregory E Hicks,et al.  Minimal detectable change for gait variables collected during treadmill walking in individuals post-stroke. , 2011, Gait & posture.

[4]  John D. Childs,et al.  Reliability of measures of impairments associated with patellofemoral pain syndrome , 2006, BMC musculoskeletal disorders.

[5]  T. Uhl,et al.  Comparison of lower extremity kinematics and hip muscle activation during rehabilitation tasks between sexes. , 2010, Journal of athletic training.

[6]  M. Eliasziw,et al.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. , 1994, Physical therapy.

[7]  M. Hunt,et al.  Lateral trunk lean explains variation in dynamic knee joint load in patients with medial compartment knee osteoarthritis. , 2008, Osteoarthritis and cartilage.

[8]  Paul DeVita,et al.  Trunk position modulates anterior cruciate ligament forces and strains during a single-leg squat. , 2012, Clinical biomechanics.

[9]  T. Hewett,et al.  The Mechanistic Connection Between the Trunk, Hip, Knee, and Anterior Cruciate Ligament Injury , 2011, Exercise and sport sciences reviews.

[10]  Anthony G. Schache,et al.  Performance on the Single-Leg Squat Task Indicates Hip Abductor Muscle Function , 2011, The American journal of sports medicine.

[11]  Irene S Davis,et al.  Lower extremity mechanics of females with and without patellofemoral pain across activities with progressively greater task demands. , 2008, Clinical biomechanics.

[12]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[13]  Dan K Ramsey,et al.  Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. , 2005, Gait & posture.

[14]  J. Wilken,et al.  Reliability and Minimal Detectible Change values for gait kinematics and kinetics in healthy adults. , 2012, Gait & posture.

[15]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[16]  T. Chmielewski,et al.  Intertask comparison of frontal plane knee position and moment in female athletes during three distinct movement tasks , 2011, Scandinavian journal of medicine & science in sports.

[17]  S. Marshall,et al.  A Prospective Investigation of Biomechanical Risk Factors for Patellofemoral Pain Syndrome , 2009, The American journal of sports medicine.

[18]  Robert Shapiro,et al.  Hip abductor function and lower extremity landing kinematics: sex differences. , 2007, Journal of athletic training.

[19]  I. Davis,et al.  Utility of the frontal plane projection angle in females with patellofemoral pain. , 2008, The Journal of orthopaedic and sports physical therapy.

[20]  T. Gill,et al.  No effect of scapular position on 3-dimensional scapular motion in the throwing shoulder of healthy professional pitchers. , 2012, Journal of sport rehabilitation.

[21]  S. Haley,et al.  Interpreting change scores of tests and measures used in physical therapy. , 2006, Physical therapy.

[22]  Thomas W Kernozek,et al.  Comparison of 2D and 3D kinematic changes during a single leg step down following neuromuscular training. , 2011, Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine.

[23]  David G Lloyd,et al.  Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion. , 2007, Journal of biomechanics.

[24]  Michael A Hunt,et al.  Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat , 2010, BMC musculoskeletal disorders.

[25]  C. Powers The influence of abnormal hip mechanics on knee injury: a biomechanical perspective. , 2010, The Journal of orthopaedic and sports physical therapy.

[26]  I. Davis,et al.  Lower Extremity Jumping Mechanics of Female Athletes with and without Patellofemoral Pain before and after Exertion , 2008, The American journal of sports medicine.

[27]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[28]  K. Guskiewicz,et al.  Gender differences in the incidence and prevalence of patellofemoral pain syndrome , 2010, Scandinavian journal of medicine & science in sports.

[29]  S Toksvig-Larsen,et al.  Validation of a functional method for the estimation of hip joint centre location. , 1999, Journal of biomechanics.