Development and laboratory‐scale testing of a fully automated online flow cytometer for drinking water analysis

Accurate and sensitive online detection tools would benefit both fundamental research and practical applications in aquatic microbiology. Here, we describe the development and testing of an online flow cytometer (FCM), with a specific use foreseen in the field of drinking water microbiology. The system incorporated fully automated sampling and fluorescent labeling of bacterial nucleic acids with analysis at 5‐min intervals for periods in excess of 24 h. The laboratory scale testing showed sensitive detection (< 5% error) of bacteria over a broad concentration range (1 × 103–1 × 106 cells mL−1) and particularly the ability to track both gradual changes and dramatic events in water samples. The system was tested with bacterial pure cultures as well as indigenous microbial communities from natural water samples. Moreover, we demonstrated the possibility of using either a single fluorescent dye (e.g., SYBR Green I) or a combination of two dyes (SYBR Green I and Propidium Iodide), thus broadening the application possibilities of the system. The online FCM approach described herein has considerable potential for routine and continuous monitoring of drinking water, optimization of specific drinking water processes such as biofiltration or disinfection, as well as aquatic microbiology research in general. © 2012 International Society for Advancement of Cytometry

[1]  Linda K. Dick,et al.  Rapid Estimation of Numbers of Fecal Bacteroidetes by Use of a Quantitative PCR Assay for 16S rRNA Genes , 2004, Applied and Environmental Microbiology.

[2]  J. Gasol,et al.  Evaluating the Flow-Cytometric Nucleic Acid Double-Staining Protocol in Realistic Situations of Planktonic Bacterial Death , 2008, Applied and Environmental Microbiology.

[3]  P. W. van der Wielen,et al.  Effect of water composition, distance and season on the adenosine triphosphate concentration in unchlorinated drinking water in the Netherlands. , 2010, Water research.

[4]  J. Block,et al.  Nucleic acid fluorochromes and flow cytometry prove useful in assessing the effect of chlorination on drinking water bacteria. , 2005, Water research.

[5]  Thomas Egli,et al.  Flow-cytometric study of vital cellular functions in Escherichia coli during solar disinfection (SODIS). , 2006, Microbiology.

[6]  Frederik Hammes,et al.  Assessment and Interpretation of Bacterial Viability by Using the LIVE/DEAD BacLight Kit in Combination with Flow Cytometry , 2007, Applied and Environmental Microbiology.

[7]  J. Fuhrman,et al.  Significance of Size and Nucleic Acid Content Heterogeneity as Measured by Flow Cytometry in Natural Planktonic Bacteria , 1999, Applied and Environmental Microbiology.

[8]  F. Srienc,et al.  A flow injection flow cytometry system for on-line monitoring of bioreactors. , 1999, Biotechnology and bioengineering.

[9]  Dick van der Kooij,et al.  Effect of water composition, distance and season on the adenosine triphosphate concentration in unchlorinated drinking water in the Netherlands. , 2010 .

[10]  Yingying Wang,et al.  Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition. , 2010, Water research.

[11]  Frederik Hammes,et al.  Cytometric methods for measuring bacteria in water: advantages, pitfalls and applications , 2010, Analytical and bioanalytical chemistry.

[12]  O. Köster,et al.  Assessing biological stability of drinking water without disinfectant residuals in a full-scale water supply system , 2010 .

[13]  Daniel Hoefel,et al.  Enumeration of water-borne bacteria using viability assays and flow cytometry: a comparison to culture-based techniques. , 2003, Journal of microbiological methods.

[14]  G. Dubelaar,et al.  CytoBuoy: a step forward towards using flow cytometry in operational oceanography* , 2000 .

[15]  P. Lebaron,et al.  Comparison of Blue Nucleic Acid Dyes for Flow Cytometric Enumeration of Bacteria in Aquatic Systems , 1998, Applied and Environmental Microbiology.

[16]  O. Köster,et al.  Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes. , 2008, Water research.

[17]  B. Welt,et al.  An ATP-based method for monitoring the microbiological drinking water quality in a distribution network , 2003 .

[18]  T. Egli,et al.  Rapid, cultivation-independent assessment of microbial viability in drinking water. , 2008, Water research.

[19]  Frederik Hammes,et al.  Kinetics of membrane damage to high (HNA) and low (LNA) nucleic acid bacterial clusters in drinking water by ozone, chlorine, chlorine dioxide, monochloramine, ferrate(VI), and permanganate. , 2011, Water research.

[20]  Bernhard Sonnleitner,et al.  Real-time on-line flow cytometry for bioprocess monitoring. , 2011, Journal of biotechnology.

[21]  T. Egli,et al.  Isolation and characterization of low nucleic acid (LNA)-content bacteria , 2009, The ISME Journal.

[22]  H. Shapiro,et al.  Accurate flow cytometric membrane potential measurement in bacteria using diethyloxacarbocyanine and a ratiometric technique. , 1999, Cytometry.

[23]  Friedrich Srienc,et al.  Automated flow cytometry for acquisition of time‐dependent population data , 2003, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[24]  Yingying Wang,et al.  Flow cytometry for fast microbial community fingerprinting. , 2012, Water research.

[25]  Rudolf Amann,et al.  Automated Enumeration of Groups of Marine Picoplankton after Fluorescence In Situ Hybridization , 2003, Applied and Environmental Microbiology.

[26]  Yingying Wang,et al.  Measurement and interpretation of microbial adenosine tri-phosphate (ATP) in aquatic environments. , 2010, Water research.