Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis

Several clinical studies have identified a strong correlation between neointimal hyperplasia following coronary stent deployment and both stent-induced arterial injury and altered vessel hemodynamics. As such, the sequential structural and fluid dynamics analysis of balloon-expandable stent deployment should provide a comprehensive indication of stent performance. Despite this observation, very few numerical studies of balloon-expandable coronary stents have considered both the mechanical and hemodynamic impact of stent deployment. Furthermore, in the few studies that have considered both phenomena, only a small number of stents have been considered. In this study, a sequential structural and fluid dynamics analysis methodology was employed to compare both the mechanical and hemodynamic impact of six balloon-expandable coronary stents. To investigate the relationship between stent design and performance, several common stent design properties were then identified and the dependence between these properties and both the mechanical and hemodynamic variables of interest was evaluated using statistical measures of correlation. Following the completion of the numerical analyses, stent strut thickness was identified as the only common design property that demonstrated a strong dependence with either the mean equivalent stress predicted in the artery wall or the mean relative residence time predicted on the luminal surface of the artery. These results corroborate the findings of the large-scale ISAR-STEREO clinical studies and highlight the crucial role of strut thickness in coronary stent design. The sequential structural and fluid dynamics analysis methodology and the multivariable statistical treatment of the results described in this study should prove useful in the design of future balloon-expandable coronary stents.

[1]  A Z Kaftanov,et al.  [Some additions to Conway's method]. , 1972, Meditsinskaia tekhnika.

[2]  R D Bogoudinov,et al.  [Protective-technological devices for blocking radiological wards]. , 1973, Meditsinskaia tekhnika.

[3]  F Joffre,et al.  Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. , 1987, The New England journal of medicine.

[4]  G. E. Mase,et al.  Continuum Mechanics for Engineers , 1991 .

[5]  R E Vlietstra,et al.  Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. , 1992, Journal of the American College of Cardiology.

[6]  W Rutsch,et al.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.

[7]  P. Teirstein,et al.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. , 1994, The New England journal of medicine.

[8]  R. Virmani,et al.  Morphologic characteristics of lesion formation and time course of smooth muscle cell proliferation in a porcine proliferative restenosis model. , 1994, Journal of the American College of Cardiology.

[9]  E. Edelman,et al.  Endovascular stent design dictates experimental restenosis and thrombosis. , 1995, Circulation.

[10]  J. Anderson,et al.  Computational fluid dynamics : the basics with applications , 1995 .

[11]  E. Regar,et al.  Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response. , 1997, Circulation.

[12]  Frederic Martini,et al.  Fundamentals of Anatomy and Physiology , 1997 .

[13]  Patrick W. Serruys,et al.  Handbook of Coronary Stents , 1997 .

[14]  E. Edelman,et al.  Pathobiologic responses to stenting. , 1998, The American journal of cardiology.

[15]  M. Leon,et al.  In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. , 1998, Journal of the American College of Cardiology.

[16]  Antonio Colombo,et al.  Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II) , 1998, The Lancet.

[17]  E. Edelman,et al.  Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury. , 1999, Circulation research.

[18]  M. Leon,et al.  Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique. , 1999, The American journal of cardiology.

[19]  R. Virmani,et al.  Pathology of acute and chronic coronary stenting in humans. , 1999, Circulation.

[20]  O. Rosales,et al.  Balloon to artery ratio, not inflation pressure, correlates with adequate stent deployment: Size is more important than pressure , 2000 .

[21]  C. Schulz,et al.  Coronary stent symmetry and vascular injury determine experimental restenosis , 2000, Heart.

[22]  G. Mintz,et al.  Coronary in-stent restenosis - predictors, treatment and prevention. , 2000, European heart journal.

[23]  Gerhard A. Holzapfel,et al.  Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science , 2000 .

[24]  J J Wentzel,et al.  Relationship Between Neointimal Thickness and Shear Stress After Wallstent Implantation in Human Coronary Arteries , 2001, Circulation.

[25]  A. Kastrati,et al.  Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. , 2003, Journal of the American College of Cardiology.

[26]  E. Sacco,et al.  Finite-element Analysis of a Stenotic Artery Revascularization Through a Stent Insertion , 2001 .

[27]  K Ulm,et al.  Restenosis after coronary placement of various stent types. , 2001, The American journal of cardiology.

[28]  Antonio Colombo,et al.  Selection of coronary stents. , 2002, Journal of the American College of Cardiology.

[29]  Renu Virmani,et al.  Morphological Predictors of Restenosis After Coronary Stenting in Humans , 2002, Circulation.

[30]  J. Gunn,et al.  Coronary artery stretch versus deep injury in the development of in-stent neointima , 2002, Heart.

[31]  Ousa,et al.  A RANDOMIZED COMPARISON OF A SIROLIMUS-ELUTING STENT WITH A STANDARD STENT FOR CORONARY REVASCULARIZATION , 2002 .

[32]  P J Prendergast,et al.  Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling. , 2003, Journal of biomechanical engineering.

[33]  Nikos Stergiopulos,et al.  Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation: Inhibition Through Reduction of Inflammation? , 2003, Circulation.

[34]  A. Kastrati,et al.  Intracoronary Stenting and Angiographic Results: Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial , 2001, Circulation.

[35]  Jeffrey W Moses,et al.  Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. , 2003, The New England journal of medicine.

[36]  William Wijns,et al.  Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS) , 2003, The Lancet.

[37]  Hun Jung,et al.  Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery , 2004 .

[38]  P. E. McHugh,et al.  The Stress–Strain Behavior of Coronary Stent Struts is Size Dependent , 2003, Annals of Biomedical Engineering.

[39]  A. Hazel,et al.  Spatial comparison between wall shear stress measures and porcine arterial endothelial permeability. , 2004, American journal of physiology. Heart and circulatory physiology.

[40]  J. Popma,et al.  The Canadian study of the sirolimus-eluting stent in the treatment of patients with long de novo lesions in small native coronary arteries (C-SIRIUS). , 2004, Journal of the American College of Cardiology.

[41]  Gregg W. Stone,et al.  A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease , 2004 .

[42]  S. Chua,et al.  Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion , 2004 .

[43]  J. LaDisa,et al.  Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation , 2003, Annals of Biomedical Engineering.

[44]  S. Silber,et al.  The NUGGET study: NIR ultra gold‐gilded equivalency trial , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[45]  F. Auricchio,et al.  Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall , 2004, Biomechanics and modeling in mechanobiology.

[46]  John F LaDisa,et al.  Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. , 2004, Journal of applied physiology.

[47]  John F LaDisa,et al.  Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening , 2005, Biomedical engineering online.

[48]  John F LaDisa,et al.  Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. , 2005, Journal of applied physiology.

[49]  John F LaDisa,et al.  Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. , 2005, American journal of physiology. Heart and circulatory physiology.

[50]  Gerhard Sommer,et al.  Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling. , 2005, American journal of physiology. Heart and circulatory physiology.

[51]  Abdul I. Barakat,et al.  Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents , 2005, Annals of Biomedical Engineering.

[52]  D. Liang,et al.  Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. , 2005, International journal of cardiology.

[53]  P. Prendergast,et al.  Cardiovascular stent design and vessel stresses: a finite element analysis. , 2005, Journal of biomechanics.

[54]  Jan J Piek,et al.  A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial. , 2005, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[55]  Gerhard A Holzapfel,et al.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. , 2005, Journal of biomechanical engineering.

[56]  Andreas O Frank,et al.  Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. , 2005, Journal of biomechanical engineering.

[57]  John F LaDisa,et al.  Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling , 2006, Biomedical engineering online.

[58]  Rupak K Banerjee,et al.  Developing pulsatile flow in a deployed coronary stent. , 2006, Journal of biomechanical engineering.

[59]  Michael Joner,et al.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. , 2006, Journal of the American College of Cardiology.

[60]  Michael R Moreno,et al.  Effects of stent design parameters on normal artery wall mechanics. , 2006, Journal of biomechanical engineering.

[61]  C. García,et al.  Influencia de la tensión de cizallamiento en la reestenosis intra-stent: estudio in vivo con reconstrucción 3D y dinámica de fluidos computacional , 2006 .

[62]  Antonio Crespo,et al.  [Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics]. , 2006, Revista espanola de cardiologia.

[63]  Weiqiang Wang,et al.  Stent expansion in curved vessel and their interactions: a finite element analysis. , 2007, Journal of biomechanics.

[64]  Ken Ikeuchi,et al.  Simulation and experimental observation of contact conditions between stents and artery models. , 2007, Medical engineering & physics.

[65]  Jiyuan Tu,et al.  Computational Fluid Dynamics: A Practical Approach , 2007 .

[66]  P. Fitzgerald,et al.  Randomized, Double-Blind, Multicenter Study of the Endeavor Zotarolimus-Eluting Phosphorylcholine-Encapsulated Stent for Treatment of Native Coronary Artery Lesions: Clinical and Angiographic Results of the ENDEAVOR II Trial , 2006, Circulation.

[67]  Isam Faik,et al.  Time-dependent 3D simulations of the hemodynamics in a stented coronary artery , 2007, Biomedical materials.

[68]  John C. Criscione,et al.  Stented artery biomechanics and device design optimization , 2007, Medical & Biological Engineering & Computing.

[69]  Rupak K Banerjee,et al.  Developed pulsatile flow in a deployed coronary stent. , 2007, Biorheology.

[70]  Gerhard A. Holzapfel,et al.  A Numerical Model to Study the Interaction of Vascular Stents with Human Atherosclerotic Lesions , 2007, Annals of Biomedical Engineering.

[71]  Matthieu De Beule Finite element stent design , 2008 .

[72]  Silvia Schievano,et al.  Simulation of Stent Deployment in a Realistic Human Coronary Artery , 2008 .

[73]  Pascal Verdonck,et al.  Realistic finite element-based stent design: the impact of balloon folding. , 2008, Journal of biomechanics.

[74]  Siamak Najarian,et al.  Analysis of wall shear stress in stented coronary artery using 3D computational fluid dynamics modeling , 2008 .

[75]  Francesco Migliavacca,et al.  Effects of different stent designs on local hemodynamics in stented arteries. , 2008, Journal of biomechanics.

[76]  P. Wriggers Nonlinear Finite Element Methods , 2008 .

[77]  Lorenza Petrini,et al.  On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method. , 2008, Journal of biomechanics.

[78]  G. Holzapfel,et al.  Experimental Studies and Numerical Analysis of the Inflation and Interaction of Vascular Balloon Catheter-Stent Systems , 2009, Annals of Biomedical Engineering.

[79]  D. Owen,et al.  Computational methods for plasticity : theory and applications , 2008 .

[80]  Siamak Najarian,et al.  Effect of Stent Geometry on Phase Shift between Pressure and Flow Waveforms in Stented Human Coronary Artery , 2008 .

[81]  Caitríona Lally,et al.  The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents. , 2009, Medical engineering & physics.

[82]  David Rubin,et al.  Introduction to Continuum Mechanics , 2009 .

[83]  Lorenza Petrini,et al.  Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry. , 2009, Medical engineering & physics.

[84]  Francesco Migliavacca,et al.  Numerical simulation of drug eluting coronary stents: Mechanics, fluid dynamics and drug release , 2009 .

[85]  Pascal Verdonck,et al.  A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations: Comparison of Three Drug-Eluting Stents , 2009, Annals of Biomedical Engineering.

[86]  Caitríona Lally,et al.  Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis , 2009, Medical & Biological Engineering & Computing.

[87]  Nandini Duraiswamy,et al.  Comparison of near-wall hemodynamic parameters in stented artery models. , 2009, Journal of biomechanical engineering.

[88]  Luoding Zhu,et al.  Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis. , 2009, Journal of applied physiology.

[89]  Pascal Verdonck,et al.  Finite element analysis of side branch access during bifurcation stenting. , 2009, Medical engineering & physics.

[90]  Gabriele Dubini,et al.  Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning , 2010, Biomechanics and modeling in mechanobiology.

[91]  Fergal J Boyle,et al.  A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery. , 2010, Biorheology.

[92]  Fergal Boyle,et al.  A Numerical Methodology to Fully Elucidate the Altered Wall Shear Stress in a Stented Coronary Artery , 2010 .

[93]  Sanjay Pant,et al.  The Influence of Strut-Connectors in Stented Vessels: A Comparison of Pulsatile Flow Through Five Coronary Stents , 2010, Annals of Biomedical Engineering.

[94]  D. Kelly,et al.  The role of vessel geometry and material properties on the mechanics of stenting in the coronary and peripheral arteries , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[95]  Shijia Zhao,et al.  The Relation Between the Arterial Stress and Restenosis Rate After , 2010 .

[96]  Wei Wu,et al.  Finite Element Shape Optimization for Biodegradable Magnesium Alloy Stents , 2010, Annals of Biomedical Engineering.

[97]  Timothy J. Gundert,et al.  Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation. , 2010, Journal of applied physiology.

[98]  Dimitrios I Fotiadis,et al.  The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans. , 2010, JACC. Cardiovascular interventions.

[99]  Caitríona Lally,et al.  Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy. , 2010, Journal of biomechanics.

[100]  Sanjay Pant,et al.  Multiobjective design optimisation of coronary stents. , 2011, Biomaterials.

[101]  David Martin,et al.  Computational structural modelling of coronary stent deployment: a review , 2011, Computer methods in biomechanics and biomedical engineering.

[102]  Claudio Chiastra,et al.  Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery. , 2011, Journal of biomechanical engineering.

[103]  L Petrini,et al.  Continuum damage model for bioresorbable magnesium alloy devices - Application to coronary stents. , 2011, Journal of the mechanical behavior of biomedical materials.

[104]  David M Martin,et al.  Drug-eluting stents for coronary artery disease: a review. , 2011, Medical engineering & physics.

[105]  P E McHugh,et al.  A corrosion model for bioabsorbable metallic stents. , 2011, Acta biomaterialia.

[106]  Timothy J. Gundert,et al.  Optical Coherence Tomography for Patient-specific 3 D Artery Reconstruction and Evaluation of Wall Shear Stress in a Left Circumflex Coronary Artery , 2011 .

[107]  Timothy J. Gundert,et al.  Optical Coherence Tomography for Patient-specific 3D Artery Reconstruction and Evaluation of Wall Shear Stress in a Left Circumflex Coronary Artery , 2011 .

[108]  Ghassan S Kassab,et al.  Impact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion , 2012, Journal of The Royal Society Interface.

[109]  Fred J. Clubb,et al.  INCREASED ARTERY WALL STRESS POST-STENTING LEADS TO GREATER INTIMAL THICKENING , 2010, Laboratory Investigation.

[110]  Shijia Zhao,et al.  ARTERIAL WALL MECHANICS AND CLINICAL IMPLICATIONS AFTER CORONARY STENTING: COMPARISONS OF THREE STENT DESIGNS , 2012 .

[111]  Timothy J. Gundert,et al.  Optimization of cardiovascular stent design using computational fluid dynamics. , 2012, Journal of biomechanical engineering.

[112]  Claudio Chiastra,et al.  Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method , 2012 .

[113]  Manolis Gavaises,et al.  Flow Patterns at Stented Coronary Bifurcations: Computational Fluid Dynamics Analysis , 2012, Circulation. Cardiovascular interventions.

[114]  A. Kastrati,et al.  [Intracoronary Stenting and Angiographic Results Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial]. , 2012, Vestnik rentgenologii i radiologii.

[115]  Kuang-Huei Lee,et al.  Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior , 2012, Comput. Aided Des..

[116]  Claire Conway,et al.  A Computational Test-Bed to Assess Coronary Stent Implantation Mechanics Using a Population-Specific Approach , 2012 .

[117]  F. Migliavacca,et al.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models , 2013, Journal of The Royal Society Interface.

[118]  John F. LaDisa,et al.  Computational Fluid Dynamics Evaluation of Equivalency in Hemodynamic Alterations Between Driver, Integrity, and Similar Stents Implanted Into an Idealized Coronary Artery , 2013 .

[119]  Ryan J. Choo,et al.  Compound Ex Vivo and In Silico Method for Hemodynamic Analysis of Stented Arteries , 2013, PloS one.

[120]  David Martin,et al.  Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents. , 2013 .

[121]  Claudio Chiastra,et al.  Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases. , 2013, Medical engineering & physics.

[122]  Fergal Boyle,et al.  Finite element analysis of balloon‐expandable coronary stent deployment: Influence of angioplasty balloon configuration , 2013, International journal for numerical methods in biomedical engineering.

[123]  Claudio Chiastra,et al.  On the necessity of modelling fluid-structure interaction for stented coronary arteries. , 2014, Journal of the mechanical behavior of biomedical materials.

[124]  R. Müller,et al.  Hemodynamics in coronary arteries with overlapping stents. , 2014, Journal of biomechanics.

[125]  Fergal J Boyle,et al.  Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation. , 2014, Medical engineering & physics.

[126]  Claudio Chiastra,et al.  Stent deformation, physical stress, and drug elution obtained with provisional stenting, conventional culotte and Tryton-based culotte to treat bifurcations: a virtual simulation study. , 2014, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[127]  Neil W Bressloff,et al.  Simulation of longitudinal stent deformation in a patient-specific coronary artery. , 2014, Medical engineering & physics.

[128]  C. M. Amatruda,et al.  Contribution of Mechanical and Fluid Stresses to the Magnitude of In-stent Restenosis at the Level of Individual Stent Struts , 2014 .

[129]  A Schiavone,et al.  Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery--finite element simulation. , 2014, Materials science & engineering. C, Materials for biological applications.