Phase aberration correction on two-dimensional conformal arrays

Two-dimensional conformal arrays are proposed to enhance low contrast lesion detection deep in the body. The arrays conform to the body maintaining good contact over a large area. To provide full three-dimensional focusing for two-dimensional imaging, such arrays are densely sampled in the scan direction (x) and coarsely sampled in the nonscan direction (y), i.e., the arrays are anisotropic. To illustrate reduction in slice thickness with increased array length in y, a two-dimensional array is synthesized using a one-dimensional, 128 element array with a 3.5 MHz center frequency. A mask is attached confining transmission and reception of acoustic waves to 2 mm in y. Using a mechanical scan system, the one-dimensional array is moved along y covering a 28.16 mm/spl times/20.0 mm aperture. Accordingly, the synthetic array has 128 elements in x and 10 elements in y. To correct for geometric irregularities due to array movement, a gelatin based phantom containing three-dimensional point targets is used for phase aberration correction. Results show that elevational beam quality is degraded if small geometric errors are not removed. Emulated conformality at the body surface and phase aberrations induced by spatial inhomogeneities in tissue are further imposed and shown to produce severe beam-forming artifacts. Two-dimensional phase aberration correction is applied and results indicate that the method is adequate to compensate for large phase excursions across the entire array. To fully realize the potential of large, two-dimensional, conformal arrays, proper two-dimensional phase aberration correction methods are necessary.<<ETX>>

[1]  M. O'Donnell,et al.  Rectilinear phased array transducer using 2-2 ceramic-polymer composite , 1990, IEEE Symposium on Ultrasonics.

[2]  M O'Donnell,et al.  Improved detectability with blocked element compensation. , 1994, Ultrasonic imaging.

[3]  R C Waag,et al.  Measurements of ultrasonic pulse arrival time and energy level variations produced by propagation through abdominal wall. , 1994, The Journal of the Acoustical Society of America.

[4]  M. O'Donnell,et al.  A phase aberration correction method for ultrasound imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  M. O'Donnell,et al.  Aberration correction on a two-dimensional anisotropic phased array (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[6]  M. O'Donnell,et al.  Correlation-based aberration correction in the presence of inoperable elements , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Gregg E. Trahey,et al.  An evaluation of transducer design and algorithm performance for two dimensional phase aberration correction , 1991, IEEE 1991 Ultrasonics Symposium,.

[8]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  E.S. Ebbini,et al.  Blocked element compensation in phased array imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  J. Kisslo,et al.  Real‐Time, Three‐Dimensional Echocardiography: Feasibility and Initial Us , 1991, Echocardiography.

[11]  W. A. Smith,et al.  The role of piezocomposites in ultrasonic transducers , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[12]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[13]  M. O’Donnell,et al.  Beam profiles and images from two-dimensional arrays , 1990, IEEE Symposium on Ultrasonics.

[14]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[15]  S. W. Smith,et al.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor. , 1989, The Journal of the Acoustical Society of America.

[16]  Daniel H. Turnbull,et al.  Simulation of B-scan images from two-dimensional transducer arrays , 1990, IEEE Symposium on Ultrasonics.

[17]  K. Katakura,et al.  Ultrasonic Probe Using Composite Piezoelectric Materials , 1985, IEEE 1985 Ultrasonics Symposium.

[18]  R C Waag,et al.  Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens. , 1991, The Journal of the Acoustical Society of America.

[19]  R C Waag,et al.  Time-shift compensation of ultrasonic pulse focus degradation using least-mean-square error estimates of arrival time. , 1992, The Journal of the Acoustical Society of America.

[20]  Trevor S. Bird,et al.  Accurate asymptotic solution for the surface field due to apertures in a conducting cylinder , 1985 .

[21]  S.W. Smith,et al.  Two-dimensional arrays for medical ultrasound , 1991, IEEE 1991 Ultrasonics Symposium,.

[22]  M. O'Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: measurements , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  D C Sullivan,et al.  Two dimensional ultrasonic beam distortion in the breast: in vivo measurements and effects. , 1992, Ultrasonic imaging.

[24]  Robert C. Waag,et al.  Measurements of ultrasonic pulse arrival time differences produced by abdominal wall specimens. , 1990, The Journal of the Acoustical Society of America.

[25]  Takuso Sato,et al.  Imaging through an inhomogeneous layer by least‐mean‐square error fitting , 1984 .