Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China.

PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 microg m(-3) were significantly higher than outdoor PM2.5 standard of 65 microg m(-3) recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R(2) of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R(2) of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic and combustion processes.

[1]  Annmarie G. Carlton,et al.  Microanalysis methods for characterization of personal aerosol exposures , 1999 .

[2]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[3]  R. Duce,et al.  Atmospheric Trace Metals at Remote Northern and Southern Hemisphere Sites: Pollution or Natural? , 1975, Science.

[4]  Cliff I. Davidson,et al.  Toxic metals in the atmosphere , 1986 .

[5]  B. Mason Principles of geochemistry , 1958 .

[6]  P. Gaarder,et al.  Quantification and characterisation of suspended particulate matter in indoor air. , 1997, The Science of the total environment.

[7]  M. Ando,et al.  INDOOR AND OUTDOOR AIR POLLUTION AND TOKYO AND BEIJING SUPERCITIES , 1996 .

[8]  U. Ackermann-Liebrich,et al.  Particulate matter < 10 μm (PM10) and total suspended particulates (TSP) in urban, rural and alpine air in Switzerland , 1995 .

[9]  D. Dockery,et al.  Particulate air pollution as a predictor of mortality in a prospective study of U.S. adults. , 1995, American journal of respiratory and critical care medicine.

[10]  Christopher Yu Hang Chao,et al.  Residential indoor PM10 and PM2.5 in Hong Kong and the elemental composition , 2002 .

[11]  Jerome O. Nriagu,et al.  A global assessment of natural sources of atmospheric trace metals , 1989, Nature.

[12]  C. Pope,et al.  Respiratory hospital admissions associated with PM10 pollution in Utah, Salt Lake, and Cache Valleys. , 1991, Archives of environmental health.

[13]  H. Ormstad,et al.  Suspended particulate matter in indoor air: adjuvants and allergen carriers. , 2000, Toxicology.

[14]  J. Schwartz,et al.  Air pollution and daily mortality: a review and meta analysis. , 1994, Environmental research.

[15]  R. Duce,et al.  Input of atmospheric trace elements and mineral matter to the Yellow Sea during the spring of a low‐dust year , 1992 .

[16]  M. Berico,et al.  Atmospheric aerosol in an urban area—measurements of TSP and PM10 standards and pulmonary deposition assessments , 1997 .

[17]  Xudong Huang,et al.  Emissions of trace elements from motor vehicles: Potential marker elements and source composition profile , 1994 .

[18]  Askar H. Choudhury,et al.  Associations between respiratory illness and PM10 air pollution. , 1997, Archives of environmental health.

[19]  Nicole A.H. Janssen,et al.  Mass concentration and elemental composition of airborne particulate matter at street and background locations , 1997 .

[20]  J D Spengler,et al.  Particle Total Exposure Assessment Methodology (PTEAM) study: distributions of aerosol and elemental concentrations in personal, indoor, and outdoor air samples in a southern California community. , 1993, Journal of exposure analysis and environmental epidemiology.

[21]  D. Lowenthal,et al.  Pollution Aerosol in the Northeast: Northeastern-Midwestern Contributions , 1985, Science.

[22]  Yang-sheng Liu,et al.  Wintertime indoor air levels of PM10, PM2.5 and PM1 at public places and their contributions to TSP. , 2004, Environment international.