Reliable RF B/E-Field Probes for Time-Domain Monitoring of EM Exposure During Medical Device Testing

This paper presents electric and magnetic probes to measure radio frequency (RF) electric and magnetic fields for measuring the time-varying RF fields used in magnetic resonance imaging (MRI). A small single loop (2 cm) and short dipole antenna (2 cm) were developed to monitor the near field magnetic and electric exposure during the medical device testing. Theoretical analysis for each designed probe was performed to convert the real time receive signals to the exposed electric and magnetic field. Probes in this paper were tuned and matched at center frequency of 127.6 MHz for 3T MRI scanners to improve the accuracy and sensitivity. Different cables were designed to reduce the E-field pick up and achieving the most accurate measurement setup. Probes were fabricated on a single sided printed circuit board, FR4 of thickness 1.57 mm and a copper thickness of $35~\mu \text{m}$ . The measured S-parameters of the magnetic and electric field probes show less than −44 and −45 dB return loss at 127.6-MHz center frequency of the RF Birdcage.

[1]  Quang M. Tieng,et al.  Equivalent circuit of a dipole antenna using frequency-independent lumped elements , 1993 .

[2]  Wei Zhang,et al.  A Simple Miniature Ultrawideband Magnetic Field Probe Design for Magnetic Near-Field Measurements , 2016, IEEE Transactions on Antennas and Propagation.

[3]  M. Kanda Standard probes for electromagnetic field measurements , 1993 .

[4]  Joël Mispelter,et al.  NMR Probeheads for Biophysical and Biomedical Experiments: Theoretical Principles and Practical Guidelines , 2006 .

[5]  Niels Kuster,et al.  A novel automated phasor measurement system for validated and traceable EMC/EMI near-field analysis , 2016, IEEE Electromagnetic Compatibility Magazine.

[6]  Constantine A. Balanis,et al.  Antenna Theory: Analysis and Design , 1982 .

[7]  M. Bock,et al.  MR safety: simultaneous B0, dΦ/dt, and dB/dt measurements on MR-workers up to 7 T , 2011, Magnetic Resonance Materials in Physics, Biology and Medicine.

[8]  Motohisa Kanda,et al.  Methodology for Standard Electromagnetic Field Measurements , 1985, IEEE Transactions on Instrumentation and Measurement.

[10]  G. Thiele,et al.  Antenna theory and design , 1981 .

[11]  Kamal Sarabandi,et al.  An Accurate Circuit Model for Input Impedance and Radiation Pattern of Two-Port Loop Antennas as E- and H-Probe , 2017, IEEE Transactions on Antennas and Propagation.

[13]  Ravi S. Menon,et al.  Time-domain monitoring of EM exposure during medical device testing , 2017, 2017 IEEE 30th Canadian Conference on Electrical and Computer Engineering (CCECE).

[14]  R. King,et al.  The loop antenna as a probe , 1964 .

[15]  M. J. Underhill,et al.  Simple circuit model of small tuned loop antenna including observable environmental effects , 2002 .