The Effect of Intermittent Low Speed Mode Upon Aortic Valve Opening in Calves Supported With a Jarvik 2000 Axial Flow Device

We assessed the effects of an axial flow left ventricular assist device (LVAD) upon aortic valve opening, pump outflow, and biologic and hematologic parameters when operated in intermittent low speed (ILS) mode. An ILS controller equipped Jarvik 2000 LVAD was implanted in six calves. Pump speed was maintained at 10,000 rpm, and pump outflow was measured throughout the study period (71 ± 6 days [mean ± SD]). Hematologic and biochemical parameters were analyzed daily for the first 10 days, weekly for the first month, and biweekly thereafter to monitor for kidney or liver dysfunction, hemolysis, bleeding, or infection. Before study termination, esmolol hydrochloride was infused to induce low cardiac output and totally impair aortic valve opening. Radiopaque cineaortography was performed over 30 second intervals (10 seconds before, 10 seconds during, and 10 seconds immediately after ILS controller activation) to assess the effect of ILS mode upon aortic valve opening. After study termination, major end organs and the major vascular tree were removed and examined macroscopically and histologically for thrombus formation and infarction; the aortic valve was examined for thickening and fusion. All pumps were explanted and examined for thrombus formation. All six calves recovered without surgical or mechanical complications. Hematologic and biochemical parameters did not change significantly between baseline and study termination. The aortic valve successfully opened when ILS mode was activated, even under low cardiac output conditions. No thrombus was detected in the major end organs and vascular tree, except for some small renal infarcts in three calves that did not affect renal function. These results indicate that operating an axial flow LVAD in ILS mode allows aortic valve opening and aortic root washout.

[1]  O. Frazier,et al.  Acquired commissural fusion of aortic valves in patients with left ventricular assist devices. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[2]  R Jarvik,et al.  LVAD power delivery: a percutaneous approach to avoid infection. , 1998, The Annals of thoracic surgery.

[3]  R K Jarvik,et al.  Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart. , 2001, The Annals of thoracic surgery.

[4]  L. Miller,et al.  Total left ventricular outflow tract obstruction due to left ventricular assist device-induced sub-aortic thrombosis in 2 patients with aortic valve bioprosthesis. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  T. Myers,et al.  Infectious complications associated with ventricular assist systems. , 2000, ASAIO journal.

[6]  O.H. Frazier,et al.  Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to Transplantation , 2004, Cardiology.

[7]  H Schmid-Schönbein,et al.  Towards a concept of thrombosis in accelerated flow: rheology, fluid dynamics, and biochemistry. , 1985, Biorheology.

[8]  Stephen Westaby,et al.  Use of the Jarvik 2000 Left Ventricular Assist System as a Bridge to Heart Transplantation or as Destination Therapy for Patients With Chronic Heart Failure , 2003, Annals of surgery.

[9]  M. Oz,et al.  In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. , 2004, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[10]  H. Harasaki,et al.  Chronic nonpulsatile blood flow. , 1982, Transactions - American Society for Artificial Internal Organs.

[11]  H. Petschek,et al.  Stagnation flow thrombus formation. , 1968, Transactions - American Society for Artificial Internal Organs.

[12]  O. Frazier,et al.  Myocardial Hemodynamics, Physiology, and Perfusion With an Axial Flow Left Ventricular Assist Device in the Calf , 2004, ASAIO journal.

[13]  H. Goldsmith,et al.  Role of blood cell-wall interactions in thrombogenesis and atherogenesis: a microrheological study. , 1984, Biorheology.

[14]  T. Hattori,et al.  Effects of left ventricular assist device on cardiac function: experimental study of relationship between pump flow and left ventricular diastolic function. , 2001, Artificial organs.

[15]  T. Myers,et al.  Left ventricular assist system as a bridge to myocardial recovery. , 1999, The Annals of thoracic surgery.

[16]  L. Miller,et al.  Partial aortic valve fusion induced by left ventricular assist device. , 2000, The Annals of thoracic surgery.

[17]  M. Oz,et al.  Partial loading of the left ventricle during mechanical assist device support is associated with improved myocardial function, blood flow and metabolism and increased exercise capacity. , 2002, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[18]  A Undar,et al.  The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model. , 1999, Artificial organs.

[19]  Stephen Westaby,et al.  Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist System , 2002, Circulation.

[20]  H Harasaki,et al.  Physiopathological studies of nonpulsatile blood flow in chronic models. , 1983, Transactions - American Society for Artificial Internal Organs.

[21]  M. Oz,et al.  Multicenter clinical evaluation of the heartmate; vented electric left ventricular assist system in patients awaiting heart transplantation. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[22]  T. Myers,et al.  Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection. , 2004, The Annals of thoracic surgery.