Secondary aerosolization of viable Bacillus anthracis spores in a contaminated US Senate Office.

CONTEXT Bioterrorist attacks involving letters and mail-handling systems in Washington, DC, resulted in Bacillus anthracis (anthrax) spore contamination in the Hart Senate Office Building and other facilities in the US Capitol's vicinity. OBJECTIVE To provide information about the nature and extent of indoor secondary aerosolization of B anthracis spores. DESIGN Stationary and personal air samples, surface dust, and swab samples were collected under semiquiescent (minimal activities) and then simulated active office conditions to estimate secondary aerosolization of B anthracis spores. Nominal size characteristics, airborne concentrations, and surface contamination of B anthracis particles (colony-forming units) were evaluated. RESULTS Viable B anthracis spores reaerosolized under semiquiescent conditions, with a marked increase in reaerosolization during simulated active office conditions. Increases were observed for B anthracis collected on open sheep blood agar plates (P<.001) and personal air monitors (P =.01) during active office conditions. More than 80% of the B anthracis particles collected on stationary monitors were within an alveolar respirable size range of 0.95 to 3.5 micro m. CONCLUSIONS Bacillus anthracis spores used in a recent terrorist incident reaerosolized under common office activities. These findings have important implications for appropriate respiratory protection, remediation, and reoccupancy of contaminated office environments.

[1]  CJ Peters,et al.  Anthrax inhalation and lethal human infection , 2002, The Lancet.

[2]  M. Hugh-jones,et al.  The Sverdlovsk anthrax outbreak of 1979. , 1994, Science.

[3]  Feller William,et al.  An Introduction To Probability Theory And Its Applications , 1950 .

[4]  A Watson,et al.  Information on which to base assessments of risk from environments contaminated with anthrax spores , 1994, Epidemiology and Infection.

[5]  P. Brachman,et al.  Industrial inhalation Anthrax. , 1966, Bacteriological reviews.

[6]  Tanja Popovic,et al.  Fatal inhalational anthrax in a 94-year-old Connecticut woman. , 2002, JAMA.

[7]  Philip K. Russell,et al.  Anthrax as a biological weapon: medical and public health management. Working Group on Civilian Biodefense. , 1999, JAMA.

[8]  K. Livak,et al.  Real time quantitative PCR. , 1996, Genome research.

[9]  A. Kaufmann,et al.  Principles for emergency response to bioterrorism. , 1999, Annals of emergency medicine.

[10]  D. W. Henderson,et al.  Studies on respiratory infection: I. The influence of particle size on respiratory infection with anthrax spores , 1953, Journal of Hygiene.

[11]  Jerome Hauer,et al.  Anthrax as a biological weapon, 2002: updated recommendations for management. , 2002, JAMA.

[12]  K. Livak,et al.  Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization. , 1995, PCR methods and applications.

[13]  P. Brachman INHALATION ANTHRAX , 1980, Annals of the New York Academy of Sciences.