Using the Cytosensor Microphysiometer to Assess Ocular Toxicity

Measuring in vitro cytotoxicity is one method currently used to estimate damage to the eye after chemical exposure. The Cytosensor Microphysiometer method evaluates cytotoxicity by measuring the test material–induced reduction in the metabolic rate of L929 cells. Changes in metabolic rate are measured indirectly as a function of changes in the extracellular acidification rate of the cells. During exposure to increasing concentrations of a cytotoxic material, there is a decrease in the release of acid byproducts into the surrounding medium as the cells die. These acidic metabolic byproducts cause a measurable change in the pH of a lightly buffered medium, which can be measured by the Cytosensor Microphysiometer. The change in the pH of the medium over time is then converted into a metabolic rate estimate for the cells. The endpoint measurement from the assay is the metabolic rate decline of 50%, the MRD50 value (in units of mg/ml). Curr. Protoc. Toxicol. 61:1.13.1‐1.13.11. © 2014 by John Wiley & Sons, Inc.

[1]  Valérie Zuang,et al.  First alternative method validated by a retrospective weight-of-evidence approach to replace the Draize eye test for the identification of non-irritant substances for a defined applicability domain. , 2010, ALTEX.

[2]  G J Carr,et al.  Assessment of the Cytosensor Microphysiometer Assay in the COLIPA In Vitro Eye Irritation Validation Study. , 1999, Toxicology in vitro : an international journal published in association with BIBRA.

[3]  O de Silva,et al.  An evaluation of five potential alternatives in vitro to the rabbit eye irritation test in vivo. , 1992, Toxicology in vitro : an international journal published in association with BIBRA.

[4]  S D Gettings,et al.  The CTFA Evaluation of Alternatives Program: an evaluation of in vitro alternatives to the Draize primary eye irritation test. (Phase III) surfactant-based formulations. , 1996, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[5]  H Spielmann,et al.  The EC/HO international validation study on alternatives to the draize eye irritation test. , 1995, Toxicology in vitro : an international journal published in association with BIBRA.

[6]  J. W. Parce,et al.  Testing ocular irritancy in vitro with the silicon microphysiometer. , 1991, Toxicology in vitro : an international journal published in association with BIBRA.

[7]  J. W. Parce,et al.  Detection of cell-affecting agents with a silicon biosensor. , 1989, Science.