Potential of gallium-based leads for cardiac rhythm management devices

We propose the use of gallium (Ga), a metal that is liquid at physiological temperatures, or one of its alloys, for use as the conducting material in the leads of implantable pacemakers or cardioverter defibrillators. It is proposed that a liquid conductor will make these leads more pliable and thus less susceptible to fracture in situ. As an initial step towards utilizing liquid gallium in leads, the biocompatibility of Ga was investigated via cytotoxicity, hemocompatibility, and intracutaneous injection testing. Unipolar pacing Ga prototypes were fabricated by adapting existing pacemaker leads. The electrical impedance and pulse transmission ability of these leads were examined. Ga was well tolerated both in vitro and in vivo. Additionally, the Ga prototypes conductors behaved as low magnitude resistances that did not distort pulses as generated by conventional pacemakers. These results indicate that Ga is an appropriate material for implantable cardiac stimulators and will be a focus of our liquid metal prototypes.

[1]  Mark A. Wood,et al.  Cardiac Pacemakers From the Patient’s Perspective , 2002 .

[2]  A Wennberg,et al.  Cytotoxicity of corroded gallium and dental amalgam alloys. An in vitro study. , 1992, Acta odontologica Scandinavica.

[3]  B. Wilkoff,et al.  Lead failures: dealing with even less perfect. , 2007, Heart rhythm.

[4]  N. Ceviz,et al.  Patient- and lead-related factors affecting lead fracture in children with transvenous permanent pacemaker. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[5]  H. Nakajima,et al.  Correlation of cytotoxicity with element release from mercury- and gallium-based dental alloys in vitro. , 1994, Dental materials : official publication of the Academy of Dental Materials.

[6]  S Hecht,et al.  Radiographic pseudofracture of bipolar pacemaker wire. , 1985, Chest.

[7]  E. Alt,et al.  Lead Fracture in Pacemaker Patients , 1987, The Thoracic and cardiovascular surgeon.

[8]  G F Tyers,et al.  Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs. , 1997, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[9]  Mark Josephson,et al.  Implantable Defibrillators and Sudden Cardiac Death , 2004, Circulation.

[10]  Robert G. Hauser,et al.  Monitoring an Imperfect Lead , 2009, Pacing and clinical electrophysiology : PACE.

[11]  U M Pandurangi,et al.  Repeated fracture of pacemaker leads with migration into the pulmonary circulation and temporary pacemaker wire insertion via the azygous vein. , 2008, Journal of postgraduate medicine.

[12]  B. Wilkoff,et al.  Pacemaker and ICD leads: Strategies for long-term management , 2008, Journal of Interventional Cardiac Electrophysiology.