Registration of emission and transmission whole-body scintillation-camera images.

UNLABELLED In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. METHODS Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an (131)I-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. RESULTS For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. CONCLUSION An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.

[1]  J S Fleming,et al.  A technique for the absolute measurement of activity using a gamma camera and computer , 1979, Physics in medicine and biology.

[2]  Colin Studholme,et al.  Automated 3-D registration of MR and CT images of the head , 1996, Medical Image Anal..

[3]  Gerald Q. Maguire,et al.  Correlation Methods for Tomographic Images Using Two and Three Dimensional Techniques , 1986 .

[4]  G. Marchal,et al.  Multi-modal volume registration by maximization of mutual information , 1997 .

[5]  J G Kereiakes,et al.  In vivo quantitation of lesion radioactivity using external counting methods. , 1976, Medical physics.

[6]  Qin-sheng Chen,et al.  Parametric imaging of patient pharmacokinetics , 1997, European Journal of Nuclear Medicine.

[7]  Michael Ljungberg,et al.  Registration of Abdominal CT and SPECT Images Using Compton Scatter Data , 1997, IPMI.

[8]  Charles R. Meyer,et al.  Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations , 1997, Medical Image Anal..

[9]  Harold O. Wyckoff,et al.  International Commission ON Radiation Units and Measurements (ICRU). , 1974, The American journal of roentgenology, radium therapy, and nuclear medicine.

[10]  R C Lanza,et al.  Development and validation of a Monte Carlo simulation of photon transport in an Anger camera. , 1990, IEEE transactions on medical imaging.

[11]  William H. Press,et al.  Numerical Recipes: FORTRAN , 1988 .

[12]  K E Britton,et al.  Kinetic analysis and probability mapping applied to the detection of ovarian cancer by radioimmunoscintigraphy. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[14]  T Ohlsson,et al.  Radioimmunotherapy using 131I-labeled anti-CD22 monoclonal antibody (LL2) in patients with previously treated B-cell lymphomas. , 1999, Clinical cancer research : an official journal of the American Association for Cancer Research.

[15]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[16]  R L Wahl,et al.  Initial results for Hybrid SPECT--conjugate-view tumor dosimetry in 131I-anti-B1 antibody therapy of previously untreated patients with lymphoma. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  F. Duck Physical properties of tissue , 1990 .

[18]  B. Wessels,et al.  MIRD pamphlet no. 16: Techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  M. Ljungberg,et al.  A Monte Carlo program for the simulation of scintillation camera characteristics. , 1989, Computer methods and programs in biomedicine.

[20]  M A Stuchly,et al.  A comparison of 60 Hz uniform magnetic and electric induction in the human body. , 1997, Physics in medicine and biology.

[21]  G Germano,et al.  Tumor quantitation and monitoring in whole-body planar technetium-99m-sestamibi imaging. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.