Model observers for complex discrimination tasks: assessments of multiple coronary stent placements

As an important clinical task, evaluating the placement of multiple coronary stents requires fine judgments of distance between stents. However, making these judgments is limited by low system resolution, noise, low contrast of the deployed stent, and stent motion during the cardiac cycle. We use task performance as a figure of merit for optimizing image display parameters. In previous work, we described our simulation procedure in detail, and also reported results of human observers for a visual task involving discrimination of 4 gap sizes under various frame rates and number of frames. Here, we report the results of three spatial model observers (i.e. NPW, NPWE, and PWMF) and two temporal sensitivity functions (i.e. transient and sustained) for the same task. Under signal known exactly conditions, we find that model observers can be used to predict human observers in terms of discrimination accuracy by adding internal noise.

[1]  Miguel P. Eckstein,et al.  Evaluation of JPEG 2000 encoder options: human and model observer detection of variable signals in X-ray coronary angiograms , 2004, IEEE Transactions on Medical Imaging.

[2]  Jay Bartroff,et al.  Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks. , 2003, Optics express.

[3]  M Eckstein,et al.  Feature stabilized digital x-ray coronary angiograms improve human visual detection in JPEG compressed images. , 1999, Optics express.

[4]  K. Mak,et al.  Clinical impact of stent construction and design in percutaneous coronary intervention. , 2004, American heart journal.

[5]  M P Eckstein,et al.  Improving detection of coronary morphological features from digital angiograms. Effect of stenosis-stabilized display. , 1994, Circulation.

[6]  Sheng Zhang,et al.  Motion and display effects on perception of multiple coronary stents , 2009, Medical Imaging.

[7]  R. F. Wagner,et al.  Application of information theory to the assessment of computed tomography. , 1979, Medical physics.

[8]  H.H. Barrett,et al.  Model observers for assessment of image quality , 1993, 2002 IEEE Nuclear Science Symposium Conference Record.

[9]  M P Eckstein,et al.  Visual signal detection in structured backgrounds. I. Effect of number of possible spatial locations and signal contrast. , 1996, Journal of the Optical Society of America. A, Optics, image science, and vision.

[10]  Sheng Zhang,et al.  Perceptual assessment of multiple stent deployment , 2008, SPIE Medical Imaging.

[11]  A. Burgess Statistically defined backgrounds: performance of a modified nonprewhitening observer model. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.