An Investigation on Ground Electrodes of Capacitive Coupling Human Body Communication

Utilizing the body surface as the signal transmission medium, capacitive coupling human body communication (CC-HBC) can achieve a much higher energy efficiency than conventional wireless communications in future wireless body area network (WBAN) applications. Under the CC-HBC scheme, the body surface serves as the forward signal path, whereas the backward path is formed by the capacitive coupling between the ground electrodes (GEs) of transmitter (TX) and receiver (RX). So the type of communication benefits from a low forward loss, while the backward loss depending on the GE coupling strength dominates the total transmission loss. However, none of the previous works have shown a complete research on the effects of GEs. In this paper, all kinds of GE effects on CC-HBC are investigated by both finite element method (FEM) analysis and human body measurement. We set the TX GE and RX GE at different heights, separation distances, and dimensions to study the corresponding influence on the overall signal transmission path loss. In addition, we also investigate the effects of GEs with different shapes and different TX-to-RX relative angles. Based on all the investigations, an analytical model is derived to evaluate the GE related variations of channel loss in CC-HBC.

[1]  Changhui Hu,et al.  A Near-Threshold, 0.16 nJ/b OOK-Transmitter With 0.18 nJ/b Noise-Cancelling Super-Regenerative Receiver for the Medical Implant Communications Service , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[2]  Jun Sakai,et al.  Balun's effect on the measurement of transmission characteristics for intrabody communication channel , 2013, 2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO).

[3]  Mario Konijnenburg,et al.  A 2.4 GHz ULP OOK Single-Chip Transceiver for Healthcare Applications , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[4]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[5]  国際非電離放射線防護委員会 ICNIRP statement on the "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)". , 2009, Health physics.

[6]  H. Nishiyama,et al.  Form and capacitance of parallel-plate capacitors , 1994 .

[7]  H. Nishiyama,et al.  Capacitance of a strip capacitor , 1990 .

[8]  Bo Zhao,et al.  A 5-tissue-layer lumped-element based HBC circuit model compatible to IEEE802.15.6 , 2015, 2015 IEEE International Symposium on Circuits and Systems (ISCAS).

[9]  George Jie Yuan,et al.  Electric-Field Intrabody Communication Channel Modeling With Finite-Element Method , 2011, IEEE Transactions on Biomedical Engineering.

[10]  Takeshi Yoshida,et al.  Wireless Multichannel Neural Recording With a 128-Mbps UWB Transmitter for an Implantable Brain-Machine Interfaces , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[11]  Javier Reina-Tosina,et al.  A Comprehensive Study Into Intrabody Communication Measurements , 2013, IEEE Transactions on Instrumentation and Measurement.

[12]  Charles Sodini,et al.  Body coupled communication: The channel and implantable sensors , 2013, 2013 IEEE International Conference on Body Sensor Networks.

[13]  Marc Simon Wegmüller,et al.  Intra-body communication for biomedical sensor networks , 2007 .

[14]  Hoi-Jun Yoo,et al.  The Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication , 2007, IEEE Transactions on Microwave Theory and Techniques.

[15]  Rizwan Bashirullah,et al.  Channel characterization for galvanic coupled in vivo biomedical devices , 2011, 2011 IEEE International Symposium of Circuits and Systems (ISCAS).

[16]  George Jie Yuan,et al.  Equation Environment Coupling and Interference on the Electric-Field Intrabody Communication Channel , 2012, IEEE Transactions on Biomedical Engineering.

[17]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[18]  Hoi-Jun Yoo,et al.  A 0.9V 2.6mW Body-Coupled Scalable PHY Transceiver for Body Sensor Applications , 2007, 2007 IEEE International Solid-State Circuits Conference. Digest of Technical Papers.

[19]  Xin Zhang,et al.  30.7 A 60Mb/s wideband BCC transceiver with 150pJ/b RX and 31pJ/b TX for emerging wearable applications , 2014, 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC).

[20]  H. Nishiyama,et al.  Capacitance of disk capacitors , 1993 .

[21]  H. Yoo,et al.  The Effects of Electrode Configuration on Body Channel Communication Based on Analysis of Vertical and Horizontal Electric Dipoles , 2015, IEEE Transactions on Microwave Theory and Techniques.

[22]  Gunar Schirner,et al.  Multi-Path Model and Sensitivity Analysis for Galvanic Coupled Intra-Body Communication Through Layered Tissue , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[23]  Javier Reina-Tosina,et al.  Distributed Circuit Modeling of Galvanic and Capacitive Coupling for Intrabody Communication , 2012, IEEE Transactions on Biomedical Engineering.