Robot-assisted microwave thermoablation of liver tumors: a single-center experience

PurposeTo evaluate and compare the needle placement accuracy, patient dose, procedural time, complication rate and ablation success of microwave thermoablation using a novel robotic guidance approach and a manual approach.MethodsWe performed a retrospective single-center evaluation of 64 microwave thermoablations of liver tumors in 46 patients (10 female, 36 male, mean age 66 years) between June 2014 and February 2015. Thirty ablations were carried out with manual guidance, while 34 ablations were performed using robotic guidance. A 6-week follow-up (ultrasound, computed tomography and MRI) was performed on all patients.ResultsThe total procedure time and dose-length product were significantly reduced under robotic guidance (18.3 vs. 21.7 min, $$p<0.001$$p<0.001; 2216 vs. 2881 mGy$$\times $$×cm, $$p = 0.04$$p=0.04). The position of the percutaneous needle was more accurate using robotic guidance (needle deviation 1.6 vs. 3.3 mm, $$p< 0.001$$p<0.001). There was no significant difference between both groups regarding the complication rate and the ablation success.ConclusionRobotic assistance for liver tumor ablation reduces patient dose and allows for fast positioning of the microwave applicator with high accuracy. The complication rate and ablation success of percutaneous microwave thermoablation of malignant liver tumors using either CT fluoroscopy or robotic guidance for needle positioning showed no significant differences in the 6-week follow-up.

[1]  Hui-Xiong Xu,et al.  Liver cancer: increased microwave delivery to ablation zone with cooled-shaft antenna--experimental and clinical studies. , 2007, Radiology.

[2]  Yasuhiko Nagano,et al.  Outcome after hepatic resection versus combined resection and microwave ablation for multiple bilobar colorectal metastases to the liver. , 2006, Surgery.

[3]  Jijo Paul,et al.  Image-guided microwave thermoablation of hepatic tumours using novel robotic guidance: an early experience , 2015, European Radiology.

[4]  M. Ogawa,et al.  Complications and Management of Microwave Coagulation Therapy for Primary and Metastatic Liver Tumors , 1998, Surgery Today.

[5]  Marc S. Schwartzberg,et al.  Quality improvement guidelines for the reporting and archiving of interventional radiology procedures. , 2003, Journal of vascular and interventional radiology : JVIR.

[6]  T. de Baère,et al.  Liver abscess after radiofrequency ablation of tumors in patients with a biliary tract procedure. , 2006, Gastroenterologie clinique et biologique.

[7]  Takashi Shibata,et al.  Microwave coagulation therapy for multiple hepatic metastases from colorectal carcinoma , 2000, Cancer.

[8]  Tomoharu Shimizu,et al.  MR-guided microwave ablation for malignancies , 2007, International Journal of Clinical Oncology.

[9]  C. Yeong,et al.  Robotic-assisted thermal ablation of liver tumours , 2015, European Radiology.

[10]  A. Stadler,et al.  CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. , 2012, European journal of radiology.

[11]  K Katada,et al.  Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. , 1996, Radiology.

[12]  D. Stoianovici,et al.  Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician. , 2002, Radiology.

[13]  Levent Kara,et al.  Radiation exposure in CT-guided interventions. , 2013, European journal of radiology.

[14]  S. Schoenberg,et al.  Evaluation of radiation exposure of medical staff during CT-guided interventions. , 2015, Journal of the American College of Radiology : JACR.

[15]  Christopher L Brace,et al.  Microwave tumor ablation: mechanism of action, clinical results, and devices. , 2010, Journal of vascular and interventional radiology : JVIR.