High force-to-volume extrusion damping devices can offer significant energy dissipation directly in structural connections and significantly reduce seismic response. Realistic force levels up to 400 kN have been obtained experimentally validating this overall concept. This paper develops spectral-based design equations for their application. Response spectra analysis for multiple, probabilistically scaled earthquake suites are used to delineate the response reductions due to added extrusion damping. Representative statistics and damping reduction factors are utilized to characterize the modified response in a form suitable for current performance-based design methods. Multiple equation regression analysis is used to characterize reduction factors in the constant acceleration, constant velocity, and constant displacement regions of the response spectra.
With peak device forces of 10% of structural weight, peak damping reduction factors in the constant displacement region of the spectra are approximately 6.5 ×, 4.0 ×, and 2.8 × for the low, medium, and high suites, respectively. At T = 1 s, these values are approximately 3.6 ×, 1.8 ×, and 1.4 ×, respectively. The maximum systematic bias introduced by using empirical equations to approximate damping reduction factors in design analyses is within the range of +10 to −20%. The seismic demand spectrum approach is shown to be conservative across a majority of the spectrum, except for large added damping between T = 0.8 and 3.5 s, where it slightly underestimates the demand up to a maximum of approximately 10%. Overall, the analysis shows that these devices have significant potential to reduce seismic response and damage at validated prototype device force levels. Copyright © 2007 John Wiley & Sons, Ltd.
[1]
Stuart S. Chen,et al.
FUNDAMENTAL CONSIDERATIONS FOR THE DESIGN OF NON-LINEAR VISCOUS DAMPERS
,
1999
.
[2]
John B. Mander,et al.
Analytical Modelling of Jointed Precast Concrete Beam-to-Column Connections with Different Damping Systems
,
2007
.
[3]
Brendon A. Bradley,et al.
Multi-Level Seismic Performance Assessment of a Damage-Protected Beam-Column Joint With Internal Lead Dampers
,
2007
.
[4]
W. H. Robinson,et al.
An extrusion energy absorber suitable for the protection of structures during an earthquake
,
1976
.
[5]
W. H. Robinson.
Recent research and applications of seismic isolation in New Zealand
,
1995
.
[6]
William Robinson,et al.
Lead‐rubber hysteretic bearings suitable for protecting structures during earthquakes
,
1982
.
[7]
John B. Mander,et al.
Experimental development and analysis of a high force/volume extrusion damper
,
2006
.
[8]
Kevin Mark Solberg.
Experimental and financial investigations into the further development of Damage Avoidance Design
,
2007
.
[9]
Yu-Yuan Lin,et al.
Effects of Site Classes on Damping Reduction Factors
,
2004
.
[10]
W. J. Cousins,et al.
Improvements to lead-extrusion damper technology
,
1993
.