A comprehensive three-dimensional radiation treatment planning system.

A comprehensive software system has been developed to allow 3-dimensional planning of radiation therapy treatments using the extensive anatomical information made available by imaging modalities such as CT and MR. Biological structures of interest and tumor volumes are defined by outlines drawn on a sequence of CT slices. Beam set-ups may then be determined in three dimensions by displaying the structure contours in a beam's eye view, or in two dimensions using a single CT cut. Each beam defined may be shaped by the specification of block aperture contours, and its intensity may be modified with the use of planar compensators. 3D dose calculation algorithms are discussed. To evaluate the calculation results, dose volume histograms are provided, as well as various types of displays in two and three dimensions, including dose on arbitrarily oriented planes, dose on the surface of anatomical objects, and isodose surfaces. Computer generated beam films are also available as an aid in patient set-up verification. These tools, and others, provide the basis for a comprehensive 3D system that can be used throughout the treatment planning process.

[1]  R. Mohan,et al.  Use of fast Fourier transforms in calculating dose distributions for irregularly shaped fields for three-dimensional treatment planning. , 1987, Medical physics.

[2]  M Goitein,et al.  Limitations of two-dimensional treatment planning programs. , 1982, Medical physics.

[3]  M. Goitein,et al.  Multi-dimensional treatment planning: II. Beam's eye-view, back projection, and projection through CT sections. , 1983, International journal of radiation oncology, biology, physics.

[4]  A. Aisen,et al.  Integration of magnetic resonance imaging into radiation therapy treatment planning: I. Technical considerations. , 1987, International journal of radiation oncology, biology, physics.

[5]  R. Mohan,et al.  Validity of the concept of separating primary and scatter dose. , 1985, Medical physics.

[6]  R L Siddon,et al.  Solution to treatment planning problems using coordinate transformations. , 1981, Medical physics.

[7]  S. McDonald,et al.  Optimization of external beam radiation therapy. , 1977, International journal of radiation oncology, biology, physics.

[8]  R Mohan,et al.  Arbitrary oblique image sections for 3-D radiation treatment planning. , 1987, International journal of radiation oncology, biology, physics.

[9]  G Starkschall,et al.  A constrained least-squares optimization method for external beam radiation therapy treatment planning. , 1984, Medical physics.

[10]  R Mohan,et al.  Extraction of pencil beam kernels by the deconvolution method. , 1988, Medical physics.

[11]  M. Patterson,et al.  Improved method for the design of tissue compensators. , 1981, Medical physics.

[12]  R Mohan,et al.  Intersection of shaped radiation beams with arbitrary image sections. , 1987, Computer methods and programs in biomedicine.

[13]  R. Mohan,et al.  Differential pencil beam dose computation model for photons. , 1986, Medical physics.

[14]  Marc Kessler,et al.  STRUCTURE TRANSFER BETWEEN SETS OF THREE DIMENSIONAL MEDICAL IMAGING DATA. , 1985 .