Performance of CMOS imager as sensing element for a Real-time Active Pixel Dosimeter for Interventional Radiology procedures

Staff members applying Interventional Radiology procedures are exposed to ionizing radiation, which can induce detrimental effects to the human body, and requires an improvement of radiation protection. This paper is focused on the study of the sensor element for a wireless real-time dosimeter to be worn by the medical staff during the interventional radiology procedures, in the framework of the Real-Time Active PIxel Dosimetry (RAPID) INFN project. We characterize a CMOS imager to be used as detection element for the photons scattered by the patient body. The CMOS imager has been first characterized in laboratory using fluorescence X-ray sources, then a PMMA phantom has been used to diffuse the X-ray photons from an angiography system. Different operating conditions have been used to test the detector response in realistic situations, by varying the X-ray tube parameters (continuous/pulsed mode, tube voltage and current, pulse parameters), the sensor parameters (gain, integration time) and the relative distance between sensor and phantom. The sensor response has been compared with measurements performed using passive dosimeters (TLD) and also with a certified beam, in an accredited calibration centre, in order to obtain an absolute calibration. The results are very encouraging, with dose and dose rate measurement uncertainties below the 10% level even for the most demanding Interventional Radiology protocols.

[1]  Filip Vanhavere,et al.  Use of active personal dosemeters in interventional radiology and cardiology: Tests in hospitals – ORAMED project , 2011 .

[2]  P. Rodríguez,et al.  Radiation effects in interventional radiology using biological and physical dosimetry methods: A case-control study , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Eliseo Vano,et al.  Occupational dosimetry in real time. Benefits for interventional radiology , 2011 .

[4]  Daniele Passeri,et al.  Characterization of standard CMOS pixel imagers as ionizing radiation detectors , 2010 .

[5]  L. Verducci,et al.  High-resolution CMOS particle detectors: design and test issues , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[6]  Radiation exposure in interventional radiology , 2007 .

[7]  Lara Struelens,et al.  Use of active personal dosemeters in interventional radiology and cardiology: Tests in laboratory conditions and recommendations - ORAMED project , 2011 .

[8]  Roberto Di Lorenzo,et al.  Use of a CMOS Image Sensor for an Active Personal Dosimeter in Interventional Radiology , 2013, IEEE Transactions on Instrumentation and Measurement.

[9]  M Luszik-Bhadra,et al.  Active personal dosemeters for individual monitoring and other new developments. , 2004, Radiation protection dosimetry.

[10]  Pisana Placidi,et al.  A real time active pixel dosimeter for interventional radiology , 2011 .