Influence of heat dumping on the operation of residential micro-CHP systems

This work deals with the effects of the heat dumping on the operation of four residential micro-CHP (combined heat and power) systems, each composed of a prime mover producing electricity and heat, a thermal energy storage system and an auxiliary boiler. The micro-CHP systems differ from one another on the prime mover, while the same multi-apartment housing situated in Italy has been considered as user. Four natural gas fueled commercial prime movers have been considered, two internal combustion engines and two microturbines, characterized by different electric and thermal powers. For each micro-CHP system, two heat-driven operation strategies, one with heat dumping and one without have been implemented by means of a home-made numerical code developed in Matlab environment, and in both the cases the economic optimization of the operation has been performed using the pattern search algorithm. For each analyzed case, the results are reported in terms of prime mover operating hours, thermal and electrical energy production, natural gas consumption, primary energy and economic savings with respect to separate generation of electricity and heat, and pollutants emission. The results of an economic analysis are also reported. The effects of the variation of the maximum capacity of the thermal energy storage system, and of the auxiliary boiler efficiency on the optimization results are analyzed, and the results relative to the two different operation strategies are compared and discussed. The major result of this study is that, for all the analyzed micro-CHP systems, an optimized application of heat dumping in the micro-CHP system operation permit to considerably reduce the size of the thermal energy storage system with respect to the heat-driven operation strategy without heat dumping.

[1]  M. Newborough,et al.  Impact of micro-CHP systems on domestic sector CO2 emissions , 2005 .

[2]  Pierluigi Mancarella,et al.  Global and local emission impact assessment of distributed cogeneration systems with partial-load models , 2009 .

[3]  Anders N. Andersen,et al.  Feasibility of CHP-plants with thermal stores in the German spot market , 2009 .

[4]  Luis M. Serra,et al.  Cost optimization of the design of CHCP (combined heat, cooling and power) systems under legal constraints , 2010 .

[5]  Andrea De Pascale,et al.  Guidelines for residential micro-CHP systems design , 2012 .

[6]  Ana C. M. Ferreira,et al.  An economic perspective on the optimisation of a small-scale cogeneration system for the Portuguese scenario , 2012 .

[7]  Carlo Roselli,et al.  Load sharing with a local thermal network fed by a microcogenerator: Thermo-economic optimization by means of dynamic simulations , 2014 .

[8]  Francesco Melino,et al.  Influence of the thermal energy storage on the profitability of micro-CHP systems for residential building applications , 2012 .

[9]  Aidong Yang,et al.  Modelling and selection of micro-CHP systems for domestic energy supply: The dimension of network-wide primary energy consumption , 2014 .

[10]  Ryohei Yokoyama,et al.  Optimal sizing of residential gas engine cogeneration system for power interchange operation from en , 2011 .

[11]  Graham Coates,et al.  Optimal online operation of residential μCHP systems using linear programming , 2012 .

[12]  P. R. Spina,et al.  Analysis of innovative micro-CHP systems to meet household energy demands , 2012 .

[13]  Martin Pehnt,et al.  Environmental impacts of distributed energy systems—The case of micro cogeneration , 2008 .

[14]  Søren Knudsen Kær,et al.  Application of an improved operational strategy on a PBI fuel cell-based residential system for Danish single-family households , 2013 .

[15]  Efstratios N. Pistikopoulos,et al.  Energy production planning of a network of micro combined heat and power generators , 2013 .

[16]  Pierluigi Mancarella,et al.  Emission characterization and evaluation of natural gas-fueled cogeneration microturbines and internal combustion engines , 2008 .

[17]  Hongbo Ren,et al.  Optimal sizing for residential CHP system , 2008 .

[18]  Željko Bogdan,et al.  A novel method for finding the optimal heat storage tank capacity for a cogeneration power plant , 2014 .

[19]  Taehoon Hong,et al.  Framework for establishing the optimal implementation strategy of a fuel-cell-based combined heat and power system: Focused on multi-family housing complex , 2014 .