Performance Evaluation of Coherence-Based Adaptive Imaging Using Clinical Breast Data

Sound-velocity inhomogencities degrade both the spatial resolution and the contrast in diagnostic ultrasound. We previously proposed an adaptive imaging approach based on the coherence of the data received in the channels of a transducer array, and we tested it on phantom data. In this study, the approach was tested on clinical breast data and compared with a correlation-based method that has been widely reported in the literature. The main limitations of the correlation-based method in ultrasonic breast imaging are the use of a near-field, phase- screen model and the integration errors due to the lack of a two-dimensional (2-D) array. In contrast, the proposed coherence-based method adaptively weights each image pixel based on the coherence of the receive-channel data. It does not make any assumption about the source of the focusing errors and has been shown to be effective using 1-D arrays. This study tested its in vivo performance using clinical breast data acquired by a programmable system with a 5 MHz, 128-channel linear array. Twenty-five cases (6 fibroadenomas, 10 carcinomas, 6 cysts, and 3 abscesses) were investigated. Relative to nonweighted imaging, the average improvements in the contrast ratio and contrast-to- noise ratio for the coherence-based method were 8.57 dB and 23.2%, respectively. The corresponding improvements when using the correlation-based method were only 0.42 dB and 3.35%. In an investigated milk-of-calcium case, the improvement in the contrast was 4.47 dB and the axial and lateral dimensions of the object were reduced from 0.39 to 0.32 mm and from 0.51 to 0.43 mm, respectively. These results demonstrate the efficacy of the coherence- based method for clinical ultrasonic breast imaging using 1-D arrays.

[1]  Gregg E. Trahey,et al.  Adaptive imaging in the breast , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[2]  M. O'Donnell,et al.  Improved estimation of phase aberration profiles , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  K. W. Rigby,et al.  Efficient parallel adaptive aberration correction , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  W. Walker,et al.  A fundamental limit on the performance of correlation based phase correction and flow estimation techniques , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  M O'Donnell,et al.  Improved detectability with blocked element compensation. , 1994, Ultrasonic imaging.

[6]  G.E. Trahey,et al.  A comparative evaluation of several algorithms for phase aberration correction , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[8]  M. O'Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: measurements , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  E.S. Ebbini,et al.  Blocked element compensation in phased array imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  D C Sullivan,et al.  In vivo measurements of ultrasonic beam distortion in the breast. , 1991, Ultrasonic imaging.

[11]  Matthew O'Donnell,et al.  Experimental Results on Phase Aberration Correction for Two-Dimensional Conformal Arrays , 1995 .

[12]  W. Walker,et al.  A comparison of the performance of time-delay estimators in medical ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  G. Trahey,et al.  In Vivo Measurements of Ultrasonic Beam Distortion in the Breast , 1991 .

[14]  W.F. Walker,et al.  Aberrator integration error in adaptive imaging , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[16]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[17]  M. O'Donnell,et al.  Adaptive compensation of phase and magnitude aberrations , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  R C Waag,et al.  Measurement and correction of ultrasonic pulse distortion produced by the human breast. , 1995, The Journal of the Acoustical Society of America.

[19]  M. O'Donnell,et al.  Coherence factor of speckle from a multi-row probe , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[20]  S. D. Silverstein,et al.  Ultrasound scattering model: 2-D cross-correlation and focusing criteria-theory, simulations, and experiments , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  Raoul Mallart,et al.  Adaptive focusing in scattering media through sound‐speed inhomogeneities: The van Cittert Zernike approach and focusing criterion , 1994 .

[22]  B.D. Steinberg,et al.  Wavefront amplitude distortion and image sidelobe levels. II. In vivo experiments , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  R C Waag,et al.  Time-shift compensation of ultrasonic pulse focus degradation using least-mean-square error estimates of arrival time. , 1992, The Journal of the Acoustical Society of America.

[24]  Pai-Chi Li,et al.  Adaptive imaging using the generalized coherence factor. , 2003, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[25]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  B. Steinberg,et al.  Wavefront amplitude distortion and image sidelobe levels. I. Theory and computer simulations , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.