Monitoring blood coagulation with magnetoelastic sensors.

The determination of blood coagulation time is an essential part of monitoring therapeutic anticoagulants. Standard methodologies for the measurement of blood clotting time require dedicated personnel and involve blood sampling procedures. A new method based on magnetoelastic sensors has been employed for the monitoring of blood coagulation. The ribbon-like magnetoelastic sensor oscillates at a fundamental frequency, which shifts linearly in response to applied mass loads or a fixed mass load of changing elasticity. The magnetoelastic sensors emit magnetic flux, which can be detected by a remotely located pick-up coil, so that no direct physical connections are required. During blood coagulation, the viscosity of blood changes due to the formation of a soft fibrin clot. In turn, this change in viscosity shifts the characteristic resonance frequency of the magnetoelastic sensor enabling real-time continuous monitoring of this biological event. By monitoring the signal output as a function of time, a distinct blood clotting profile can be seen. The relatively low cost of the magnetoelastic ribbons enables their use as disposable sensors. This, along with the reduced volume of blood required, make the magnetoelastic sensors well suited for at-home and point-of-care testing devices.

[1]  C A Grimes,et al.  A wireless, remote query ammonia sensor. , 2001, Sensors and actuators. B, Chemical.

[2]  C A Grimes,et al.  Remote query measurement of pressure, fluid-flow velocity, and humidity using magnetoelastic thick-film sensors. , 2000, Sensors and actuators. A, Physical.

[3]  B Liedberg,et al.  Blood plasma coagulation studied by surface plasmon resonance. , 2000, Journal of biomedical optics.

[4]  C. Grimes,et al.  Viscosity measurements of viscous liquids using magnetoelastic thick-film sensors , 2000 .

[5]  T. Cheng,et al.  A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood. , 1998, Biosensors & bioelectronics.

[6]  H. Chiriac,et al.  Fe-based amorphous thin film as a magnetoelastic sensor material , 2000 .

[7]  I Lundström,et al.  Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assay. , 1999, Biosensors & bioelectronics.

[8]  Craig A. Grimes,et al.  Simultaneous measurement of liquid density and viscosity using remote query magnetoelastic sensors , 2000 .

[9]  Craig A. Grimes,et al.  A salt-independent pH sensor , 2001 .

[10]  Craig A. Grimes,et al.  Magnetism-Based Remote Query Glucose Sensors , 2001 .

[11]  Craig A. Grimes,et al.  The frequency response of magnetoelastic sensors to stress and atmospheric pressure , 2000 .

[12]  I Lundström,et al.  Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulation. , 2000, Biosensors & bioelectronics.

[13]  I Karube,et al.  A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector. , 1991, Biosensors & bioelectronics.

[14]  C. Grimes,et al.  A remote query magnetoelastic pH sensor. , 2000, Sensors and actuators. B, Chemical.

[15]  Antonio DeSimone,et al.  A constrained theory of magnetoelasticity , 2002 .

[16]  Hsien-Chang Chang,et al.  Determination of coagulation time in whole blood containing anticoagulant by piezoelectric quartz crystal sensor , 2000 .

[17]  Craig A. Grimes,et al.  A wireless magnetoelastic micro-sensor array for simultaneous measurement of temperature and pressure , 2001 .

[18]  C. Sultan,et al.  Manual of hematology , 1985 .

[19]  E. Hristoforou,et al.  Magneto-surface-acoustic-waves microdevice using thin film technology : design and fabrication process , 2001 .

[20]  B. A. Brown Hematology: Principles and Procedures , 1973 .