ASTEROID: A new 64 channel ASIC for source follower based readout of the MIXS DEPFET arrays on BepiColombo

ASTEROID is a new 64 channel ASIC developed to read out a DEPFET macropixel array. This sensor will be part of the MIXS instrument that will be used in the ESA's BepiColombo Mercury exploration mission. The detector will operate in an environment with high density of solar proton flux that will cause severe radiation damage and an increase of leakage current during mission lifetime. Given the relatively high value of the leakage current, a high speed readout and a proper cooling of the detector is needed in order to achieve the required energy resolution. The contribution of the readout electronics to the noise should be smaller than 10 electrons r.m.s. The foreseen pixel arrays are optimized for source follower readout. In this operating mode of the DEPFETs, the readout electronics is AC-coupled. This allows easy coping with non homogeneity of the pixel matrix and - most of all - an easy compensation of threshold voltage shifts of the DEPFET devices due to radiation damage. In order to achieve the low noise value required at short processing time, ASTEROID implements a trapezoidal weighting function, which represents the time-limited optimum filter for white series noise. This is the major electronics noise source at the foreseen readout speed. Measurements on a first prototype of the ASIC have shown the very satisfactory resolution of 147 eV on Mn-Kalphapeak of 55Fe with a readout time of approximately 1.2 mus, that would lead, considering the settling time of the DEPFET, to a total processing time of 4.2 mus. We present the experimental results of a first prototype that includes 4 analog channels and a new digital section for the generation of the timing signals of the circuit. This digital section is based on radiation- hardened dual-port memory cells and registers and has already been implemented to serve all the 64 channels foreseen for the final version of the ASIC.

[1]  Carlo Fiorini,et al.  Theoretical comparison between two different filtering techniques suitable for the VLSI spectroscopic amplifier ROTOR , 2003 .

[2]  H. Soltau,et al.  DEPFET based focal plane instrumentation for X-ray imaging spectroscopy in space , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  Matteo Porro,et al.  Sub-electron noise measurements on repetitive non-destructive readout devices , 2006 .

[4]  R. Grard BepiColombo – A Multidisciplinary Mission to a Hot Planet , 2000 .

[5]  M. Trimpl,et al.  Spectroscopic performances of DePMOS detector/amplifier device with respect to different filtering techniques and operating conditions , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[6]  T. Calin,et al.  Upset hardened memory design for submicron CMOS technology , 1996 .

[7]  M. Porro,et al.  Multi correlated double sampling with exponential reset , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[8]  S. Herrmann,et al.  A new silicon detector system for optical and low light imaging, based on DEPFET RNDR , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[9]  R. Hartmann,et al.  Mixed signal pnCCD readout ASIC for the future X-Ray astronomy mission eROSITA , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[10]  Marco Sampietro,et al.  Optimum filters for detector charge measurements in presence of {1}/{f} noise , 1990 .

[11]  G. Geelen,et al.  An inherently linear and compact MOST-only current division technique , 1992 .

[12]  Matteo Porro,et al.  Development of DEPFET Macropixel detectors , 2006 .

[13]  Johannes Benkhoff,et al.  BepiColombo: Payload and mission updates , 2006 .