An Extension–Distraction Injury of the Thoracic Spine with Traumatic Partial Correction of Thoracic Kyphosis

Abstract Study Design The study is a case report. Objective The authors aim to report an unusual injury pattern in a patient previously treated for thoracic kyphoscoliosis. Methods A postoperative (computed tomography) CT of a healthy 24-year-old man who underwent posterior instrumentation and fusion for a kyphoscoliosis deformity was compared with a CT performed after a motor vehicle accident (MVA) 1 year later, which resulted in an extension–distraction injury of T8 with no neurologic deficit. Cobb angles of the thoracic sagittal images of both CTs were measured using a digital measuring device and the values were recorded. Results Initial postoperative sagittal CT images demonstrate a 67-degree residual thoracic kyphosis compared with the post-MVA sagittal CT images, which reveal a 54-degree thoracic kyphosis, a 13-degree improvement in sagittal alignment. Conclusion It is unusual for a patient with long posterior instrumentation of the spine to sustain a spinal fracture without breakage of the rods, which were 6-mm nickel–titanium alloy with two crosslinks. Although sustaining plastic deformation, the rods maintained their integrity to the degree that the patient required no subsequent treatment to his spine at 12 months follow-up. It is rare to sustain a vertebral fracture without implant failure, which occurred in this case.

[1]  J. Chapman,et al.  Spine Fractures in Patients With Ankylosing Spinal Disorders , 2010, Spine.

[2]  S. Morgan,et al.  Management of a Trochanteric Fracture Complicated by a Bent Solid Intramedullary Femoral Nail In Situ: Description of Technique , 2010, Journal of orthopaedic trauma.

[3]  Xiaoming Jiang,et al.  [Histological observation of microscrews anchorage implant-bone interface loaded with different orthodontic condition]. , 2008, Shanghai kou qiang yi xue = Shanghai journal of stomatology.

[4]  C. Bellabarba,et al.  Three-Column Ligamentous Extension Injury of the Thoracic Spine: A Case Report and Review of the Literature , 2007, Spine.

[5]  S. Parent,et al.  Titanium Versus Stainless Steel for Anterior Spinal Fusions: An Analysis of Rod Stress as a Predictor of Rod Breakage During Physiologic Loading in a Bovine Model , 2007, Spine.

[6]  J. Buckwalter,et al.  Orthopaedic basic science : foundations of clinical practice , 2007 .

[7]  R. Reimer,et al.  Early complications of posterior rod-screw fixation of the cervical and upper thoracic spine. , 2006, Neurosurgery.

[8]  M. Solomonow,et al.  The Memory Properties of Cold-Worked Titanium Rods in Scoliosis Constructs , 2005, Spine.

[9]  Thomas R Oxland,et al.  Thoracolumbar spine mechanics contrasted under compression and shear loading , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  L. Yahia,et al.  Characteristics of porous nickel-titanium alloys for medical applications. , 2002, Bio-medical materials and engineering.

[11]  M. Dalstra,et al.  Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel , 2000, European Spine Journal.

[12]  K. Leung,et al.  Treatment of deformed tibial intramedullary nail: report of two cases. , 1996, Journal of orthopaedic trauma.

[13]  J. Silver,et al.  The causes of failure of lumbar transpedicular spinal instrumentation and fusion , 1996, International Orthopaedics.

[14]  P. McAfee,et al.  Survivorship Analysis of Pedicle Spinal Instrumentation , 1991, Spine.