Implantable magnetic relaxation sensors measure cumulative exposure to cardiac biomarkers

Molecular biomarkers can be used as objective indicators of pathologic processes. Although their levels often change over time, their measurement is often constrained to a single time point. Cumulative biomarker exposure would provide a fundamentally different kind of measurement to what is available in the clinic. Magnetic resonance relaxometry can be used to noninvasively monitor changes in the relaxation properties of antibody-coated magnetic particles when they aggregate upon exposure to a biomarker of interest. We used implantable devices containing such sensors to continuously profile changes in three clinically relevant cardiac biomarkers at physiological levels for up to 72 h. Sensor response differed between experimental and control groups in a mouse model of myocardial infarction and correlated with infarct size. Our prototype for a biomarker monitoring device also detected doxorubicin-induced cardiotoxicity and can be adapted to detect other molecular biomarkers with a sensitivity as low as the pg/ml range.

[1]  C. Velican,et al.  Silent myocardial ischemia. , 1989, Medecine interne.

[2]  R Weissleder,et al.  High-efficiency intracellular magnetic labeling with novel superparamagnetic-Tat peptide conjugates. , 1999, Bioconjugate chemistry.

[3]  M. R. Anoop,et al.  The present and future , 2001 .

[4]  B. Gersh,et al.  Unrecognized Myocardial Infarction , 2001, Annals of Internal Medicine.

[5]  R. Weissleder,et al.  A New Platform for the Development of Targeted MR Contrast Agents 1 , 2002 .

[6]  Ralph Weissleder,et al.  Crosslinked iron oxides (CLIO): a new platform for the development of targeted MR contrast agents. , 2002, Academic radiology.

[7]  Ralph Weissleder,et al.  DNA-based magnetic nanoparticle assembly acts as a magnetic relaxation nanoswitch allowing screening of DNA-cleaving agents. , 2002, Journal of the American Chemical Society.

[8]  Ralph Weissleder,et al.  Magnetic relaxation switches capable of sensing molecular interactions , 2002, Nature Biotechnology.

[9]  Ralph Weissleder,et al.  Magnetic sensors for protease assays. , 2003, Angewandte Chemie.

[10]  Ralph Weissleder,et al.  Use of Magnetic Nanoparticles as Nanosensors to Probe for Molecular Interactions , 2004, Chembiochem : a European journal of chemical biology.

[11]  Ralph Weissleder,et al.  Magnetic relaxation switch immunosensors detect enantiomeric impurities. , 2004, Angewandte Chemie.

[12]  Frank D Sistare,et al.  Serum Troponins as Biomarkers of Drug-Induced Cardiac Toxicity , 2004, Toxicologic pathology.

[13]  Jan A Kors,et al.  Defining unrecognized myocardial infarction: a call for standardized electrocardiographic diagnostic criteria. , 2004, American heart journal.

[14]  Qing Nie,et al.  Mouse cardiac surgery: comprehensive techniques for the generation of mouse models of human diseases and their application for genomic studies. , 2004, Physiological genomics.

[15]  Raymond J Kim,et al.  Infarct morphology identifies patients with substrate for sustained ventricular tachycardia. , 2005, Journal of the American College of Cardiology.

[16]  Ralph Weissleder,et al.  Continuous analyte sensing with magnetic nanoswitches. , 2006, Small.

[17]  Mikhail G. Shapiro,et al.  Dynamic imaging with MRI contrast agents: quantitative considerations. , 2006, Magnetic resonance imaging.

[18]  Fred S Apple,et al.  Biomarkers in acute cardiac disease: the present and the future. , 2006, Journal of the American College of Cardiology.

[19]  G. Takemura,et al.  Doxorubicin-induced cardiomyopathy from the cardiotoxic mechanisms to management. , 2007, Progress in cardiovascular diseases.

[20]  Robert Langer,et al.  Multi-reservoir device for detecting a soluble cancer biomarker. , 2007, Lab on a chip.

[21]  J. Robert Long-term and short-term models for studying anthracycline cardiotoxicity and protectors , 2007, Cardiovascular Toxicology.

[22]  Robert Langer,et al.  Magnetic relaxation switch detection of human chorionic gonadotrophin. , 2007, Bioconjugate chemistry.

[23]  M. Cima,et al.  Multiparameter magnetic relaxation switch assays. , 2007, Analytical chemistry.

[24]  Sebastian Kelle,et al.  Comparison of myocardial infarct size assessed with contrast-enhanced magnetic resonance imaging and left ventricular function and volumes to predict mortality in patients with healed myocardial infarction. , 2007, The American journal of cardiology.

[25]  M. Picard,et al.  Infarct Size Assessment in Mice , 2007, Echocardiography.

[26]  Jeroen J. Bax,et al.  Universal definition of myocardial infarction. , 2007 .

[27]  Robert Langer,et al.  Implantable diagnostic device for cancer monitoring. , 2009, Biosensors & bioelectronics.