Energy impacts of heat island reduction strategies in the Greater Toronto Area, Canada

In 2000, the Toronto Atmospheric Fund (TAF) embarked on an initiative to quantify the potential benefits of Heat Island Reduction (HIR) strategies (shade trees, reflective roofs and pavements) in reducing cooling energy use in buildings, lowering the ambient air temperature and improve air quality. This report summarizes the efforts of Lawrence Berkeley National Laboratory (LBNL) to assess the impacts of HIR measures on building cooling- and heating-energy use. We discuss our efforts to calculate annual energy savings and peak-power avoidance of HIR strategies in the building sector of the Greater Toronto Area. The analysis is focused on three major building types that offer most saving potentials: residence, office and retail store. Using an hourly building energy simulation model, we quantify the energy saving potentials of (1) using cool roofs on individual buildings [direct effect], (2) planting deciduous shade trees near south and west walls of building [direct effect], (3) planting coniferous wind-shielding vegetation near building [direct effect], (4) ambient cooling by a large-scale program of urban reforestation with reflective building roofs and pavements [indirect effect], (5) and the combined direct and indirect effects. Results show potential annual energy savings of over $11M (with uniform residential and commercial electricity and gas prices of $0.084/kWh and $5.54/GJ) could be realized by ratepayers from the combined direct and indirect effects of HIR strategies. Of that total, about 88 percent was from the direct impact roughly divided equally among reflective roofs, shade trees and wind-shielding, and the remainder (12 percent) from the indirect impact of the cooler ambient air temperature. The residential sector accounts for over half (59 percent) of the total, offices 13 percent and retail stores 28 percent. Savings from cool roofs were about 20 percent, shade trees 30 percent, wind shielding of tree 37 percent, and indirect effect 12 percent. These results are highly sensitive to the price of gas. Assuming a residential gas price of $10.84/GJ (gas price during December 2001), the net annual savings are reduced to about $10M; about 78 percent resulted from wind-shielding, 16 percent from shading by trees, and 5 percent from cool roofs. Potential annual electricity savings were estimated at about 150GWh or over $12M, of that about 75 percent accrued from roofs and shade trees and only 2 percent from wind shielding. The indirect effect was 23 percent. Potential peak-power avoidance was estimated at 250MW with about 74 percent attributed to the direct impacts (roofs about 24 percent, shade trees 51 percent and wind-shielding a small negative percent) and the remainder (26 percent) to the indirect impact. The greatest part of avoided peak power (about 83 percent (was because of the effects of the residences and the rest shared by offices (7 percent) and retail stores (9 percent).

[1]  Hashem Akbari,et al.  Peak power and cooling energy savings of shade trees , 1997 .

[2]  S. Konopacki Simulated Impact of Roof Surface Solar Absorptance, Attic, and Duct Insulation, and Duct Insulation on Cooling and Heating Energy Use in Single-Family Residential Buildings , 1998 .

[3]  Hashem Akbari,et al.  Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin , 2001 .

[4]  S. Konopacki,et al.  Demonstration of Energy Savings of Cool Roofs , 1998 .

[5]  S. Konopacki,et al.  Modeling the effects of reflective roofing , 1996 .

[6]  S. Konopacki,et al.  Cooling energy savings potential of light-colored roofs for residential and commercial buildings in 11 US metropolitan areas , 1997 .

[7]  H. Akbari,et al.  Simulated Impact of Roof Solar Absorptance, Attic, and DuctInsulation, and Climate on Cooling and Heating Energy Use inSingle-Family Resi dential Buildings , 1998 .

[8]  Hugh Henderson,et al.  Residential equipment part load curves for use in DOE-2 , 1999 .

[9]  H. Akbari,et al.  Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas , 2001 .

[10]  N. S. Barnett,et al.  Private communication , 1969 .

[11]  H. Akbari,et al.  Calculations for reflective roofs in support of Standard 90.1 , 1998 .

[12]  H. Akbari,et al.  Long-term performance of high-albedo roof coatings , 1997 .

[13]  F. C. Winkelmann,et al.  Overview of the DOE-2 Building Energy Analysis Program , 1985 .

[14]  H. Akbari,et al.  The impact of trees and white surfaces on residential heating and cooling energy use in four Canadian cities , 1992 .

[15]  Leo Rainer,et al.  Measured Energy Savings from the Application of Reflective Roofs in 3 AT and T Regeneration Buildings , 2000 .

[16]  R. Moore,et al.  Assessing the impacts of white roofs on building energy loads , 1998 .

[17]  Max H. Sherman,et al.  Variability in Residential Air Leakage , 1986 .

[18]  Arthur H. Rosenfeld,et al.  Summer heat islands, urban trees, and white surfaces , 1990 .

[19]  Hashem Akbari,et al.  Peak power and cooling energy savings of high-albedo roofs , 1997 .

[20]  G. Grell,et al.  A description of the fifth-generation Penn State/NCAR Mesoscale Model (MM5) , 1994 .

[21]  J. J. Hirsch,et al.  DOE-2 supplement: Version 2.1E , 1993 .

[22]  H. Akbari,et al.  Energy Savings Calculations for Heat Island Reduction Strategies in Baton Rouge, Sacramento and Salt Lake City , 2000 .

[23]  Danny S. Parker,et al.  Measured performance of a reflective roofing system in a Florida commercial building , 1998 .

[24]  Danny S. Parker,et al.  Demonstration of Cooling Savings of Light Colored Roof Surfacing in Florida Commercial Buildings: Retail Strip Mall , 2002 .

[25]  L. Gu,et al.  Measured and simulated performance of reflective roofing systems in residential buildings , 1998 .