Establish of the prediction system of chest skin motion with SSA method
暂无分享,去创建一个
This paper proposes the method to establish of the prediction system of chest skin motion with SSA method. The Singular Spectrum Analysis (SSA) was applied for the prediction of time series data. A simulation system was developed to predict the location of some points of chest skin during breathing. CCD camera motion capture system (KEYENCE, CV-035C) was used to get the time series data. The prediction results s howed good agreement with the measured data and they showed hopeful possibility to realize the chasing radiotherapy te chnique.
[1] U. Topal,et al. Transthoracic needle biopsy: factors effecting risk of pneumothorax. , 2003, European journal of radiology.
[2] Ying Cui,et al. Robust fluoroscopic respiratory gating for lung cancer radiotherapy without implanted fiducial markers. , 2007, Physics in medicine and biology.
[3] H. Shirato,et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.