Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality.

Council Directive 97/43/Euratom (Medical Exposure Directive) states that member States of the European Union shall promote the establishment and use of diagnostic reference levels for radio-diagnostic examinations. Dose surveys can form the basis for the establishment of diagnostic reference levels. In view of the implementation of the Medical Exposure Directive in the Netherlands, a survey of dose and image quality has been performed for posteroanterior (PA) chest radiography in 2001. In this survey, 25 participants were selected from a list of 175 Dutch hospitals, whereas in a previous PA chest survey (about 10 years ago) participation was voluntary and participants came predominantly from the south-western part of the Netherlands. For conventional screen-film PA chest radiography, the present results for patient dose and image quality are quite similar to those results from the previous survey. The fraction of conventional X-ray systems utilizing lung compensation filters has remained approximately the same. For dedicated digital chest radiography systems, image quality is better than for conventional systems, but doses vary and can assume relatively high values. The results indicate that there are still possibilities for dose reduction, without loss of image quality. The 75 percentile value of the entrance surface dose distribution is approximately 0.13 mGy.

[1]  P.J.H. Kicken,et al.  Guidelines for Quality Control of Equipment Used in Diagnostic Radiology in the Netherlands , 1998 .

[2]  J. J. Broerse,et al.  Image Quality and Dosimetric Aspects of Chest X Ray Examinations: Measurements with Various Types of Phantoms , 1993 .

[3]  P. Kicken Radiation dosimetry in vascular radiology : organ and effective dose to patients and staff , 1996 .

[4]  J. J. Broerse,et al.  A comparison of patient dose for examinations of the upper gastrointestinal tract at 11 conventional and digital X-ray units in The Netherlands. , 1998, The British journal of radiology.

[5]  J. Zoetelief,et al.  European Intercomparison of Diagnostic Dosemeters: Results , 1992 .

[6]  A R Cowen,et al.  A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography. , 1998, Medical physics.

[7]  D. Košutić,et al.  Patient dosimetry in diagnostic radiology , 2003 .

[8]  C E Ravin,et al.  Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs. , 1995, AJR. American journal of roentgenology.

[9]  Johannes Zoetelief,et al.  Determination of Image Quality in Relation to Absorbed Dose in Mammography , 1993 .

[10]  Untere Tracheahälfte,et al.  Kann die digitale Selenradiographie in der Thoraxdiagnostik die analoge Röntgenaufnahmetechnik ersetzen? , 1997 .

[11]  J. Geleijns,et al.  Calculation of dose conversion factors for posterior-anterior chest radiography of adults with a relatively high-energy X-ray spectrum. , 1994, The British journal of radiology.

[12]  J. J. Broerse,et al.  Survey of CT techniques and absorbed dose in various Dutch hospitals. , 1997, The British journal of radiology.

[13]  B. Krug,et al.  Vergleich der digitalen Selenradiographie mit einem analogen Film-Folien-System in der Diagnostik von Staublungenerkrankungen anhand der ILO-Klassifikation , 2001 .

[14]  M. Tapiovaara,et al.  PCXMC. A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations , 1997 .

[15]  N Petoussi-Henss,et al.  Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods. , 1998, Physics in medicine and biology.

[16]  T. R. Fewell,et al.  Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinations. , 1984, Medical physics.

[17]  U. Tylén,et al.  Image quality for five modern chest radiography techniques: a modified FROC study with an anthropomorphic chest phantom , 1999, European Radiology.

[18]  H A Vrooman,et al.  AMBER and conventional chest radiography: comparison of radiation dose and image quality. , 1992, Radiology.

[19]  Arnold R. Cowen,et al.  A Case Study into the Effect of Radiographic Factors on Image Quality and Dose for a Selenium Based Digital Chest Radiography System , 1998 .

[20]  W. Teeuwisse,et al.  Patient dose due to colon examination: dose assessment and results from a survey in The Netherlands. , 1997, Radiology.