Multienzyme-modified biosensing surface for the electrochemical analysis of aspartate transaminase and alanine transaminase in human plasma

AbstractWe investigated the electrochemical detection of aspartate transaminase (AST) and alanine transaminase (ALT) by using a multienzyme-modified electrode surface. Determination of the activities of transaminases in human serum is clinically significant because their concentrations and ratios indicate the presence of hepatic diseases or myocardial dysfunction. For electrochemical detection of AST and ALT, enzymes that participate in the reaction mechanism of AST and ALT, such as pyruvate oxidase (POX) and oxaloacetate decarboxylase, were immobilized on an electrode surface by using an amine-reactive self-assembled monolayer and a homobifunctional cross-linker. In the presence of suitable substrates such as l-aspartate (l-alanine) and α-ketoglutarate, AST and ALT generate pyruvate as an enzymatic end product. To determine the activities of AST and ALT, electroanalyses of pyruvate were conducted using a POX and ferrocenemethanol electron shuttle. Anodically generated oxidative currents from multienzyme-mediated reactions were correlated to AST and ALT levels in human plasma. On the basis of the electrochemical analysis, we obtained calibration results for AST and ALT concentrations from 7.5 to 720 units/L in human plasma-based samples, covering the required clinical detection range. FigurePOX-OAC calatytic cycles for AST and ALT analysis

[1]  M. Christensen,et al.  Optimal Diagnosis in Acute Myocardial Infarction: A Cost‐effectiveness Study , 1980, Circulation.

[2]  M. Kaplan,et al.  Evaluation of abnormal liver-enzyme results in asymptomatic patients. , 2000, The New England journal of medicine.

[3]  R. Testa,et al.  Validity and clinical utility of the aspartate aminotransferase-alanine aminotransferase ratio in assessing disease severity and prognosis in patients with hepatitis C virus-related chronic liver disease. , 2003, Archives of internal medicine.

[4]  P. Coulet,et al.  Pyruvate oxidase and oxaloacetate decarboxylase enzyme electrodes : Simultaneous Determination of Transaminases with a Two-electrode-based Analyzer , 1989 .

[5]  David L. Kaplan,et al.  Molecular assembly of multilayer enzyme: toward the development of a chemiluminescence-based fiber optic biosensor , 1996 .

[6]  Frieder W. Scheller,et al.  A Pyruvate Oxidase Electrode Based on an Electrochemically Deposited Redox Polymer , 1999 .

[7]  M. Hori,et al.  Immunological determination of serum m-AST activity in patients with acute myocardial infarction. , 1978, British heart journal.

[8]  R. Renneberg,et al.  A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater , 2004, Applied Microbiology and Biotechnology.

[9]  Yang-Kyu Choi,et al.  Aspartate Aminotransferase (AST/GOT) and Alanine Aminotransferase (ALT/GPT) Detection Techniques , 2006, Sensors (Basel, Switzerland).

[10]  H. S. Kim,et al.  Functionalization of a poly(amidoamine) dendrimer with ferrocenyls and its application to the construction of a reagentless enzyme electrode. , 2000, Analytical chemistry.

[11]  D. B. Hibbert,et al.  The Development of a Pyruvate Biosensor Using Electrodeposited Polytyramine , 2002 .

[12]  F. Gordon,et al.  AST/ALT Ratio Predicts Cirrhosis in Patients With Chronic Hepatitis C Virus Infection , 1998, American Journal of Gastroenterology.

[13]  A Warsinke,et al.  Operation of a miniature redox hydrogel-based pyruvate sensor in undiluted deoxygenated calf serum. , 2000, Analytical chemistry.

[14]  D. Mozaffarian,et al.  Elevated serum alanine aminotransferase activity and calculated risk of coronary heart disease in the United States , 2006, Hepatology.

[15]  M. Panteghini,et al.  IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase , 2002 .

[16]  E. Choi,et al.  Development of an electrochemical immunosensor for alanine aminotransferase. , 2003, Biosensors & bioelectronics.

[17]  B. Piro,et al.  Reagentless recycling of pyruvate oxidase on a conducting polymer-modified electrode , 2006 .

[18]  R. Golbik,et al.  Radical phosphate transfer mechanism for the thiamin diphosphate- and FAD-dependent pyruvate oxidase from Lactobacillus plantarum. Kinetic coupling of intercofactor electron transfer with phosphate transfer to acetyl-thiamin diphosphate via a transient FAD semiquinone/hydroxyethyl-ThDP radical pair. , 2005, Biochemistry.

[19]  Jean-Marc Laval,et al.  Enzymatic Electrocatalysis Studies of Escherichia Coli Pyruvate Oxidase, Incorporated into a Biomimetic Supported Bilayer , 1998 .

[20]  Wen-Lin Hsu,et al.  Determination of glutamate pyruvate transaminase activity in clinical specimens using a biosensor composed of immobilized l-glutamate oxidase in a photo-crosslinkable polymer membrane on a palladium-deposited screen-printed carbon electrode , 2003 .

[21]  Sanjay Upadhyay,et al.  Determination of the activities of glutamic oxaloacetic transaminase and glutamic pyruvic transaminase in a microfluidic system. , 2007, Biosensors & bioelectronics.

[22]  B. D. Malhotra,et al.  Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor. , 2007, The Analyst.

[23]  J. Lott,et al.  Diagnosis and monitoring of hepatic injury. I. Performance characteristics of laboratory tests. , 2000, Clinical chemistry.

[24]  Kim,et al.  Multilayered assembly of dendrimers with enzymes on gold: thickness-controlled biosensing interface , 2000, Analytical chemistry.

[25]  E. Akyilmaz,et al.  A novel biosensor based on activation effect of thiamine on the activity of pyruvate oxidase. , 2008, Biosensors & bioelectronics.

[26]  J. Salonen,et al.  Ultrasonographically assessed carotid morphology and the risk of coronary heart disease. , 1991, Arteriosclerosis and thrombosis : a journal of vascular biology.

[27]  Seung-Cheol Chang,et al.  The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. , 2006, Biosensors & bioelectronics.

[28]  Lothar Siekmann,et al.  IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase. , 2002, Clinical chemistry and laboratory medicine.

[29]  K. Schleifer,et al.  Purification and biochemical characterization of pyruvate oxidase from Lactobacillus plantarum , 1984, Journal of bacteriology.

[30]  I. Karube,et al.  Determination of glutamate pyruvate transaminase and pyruvate with an amperometric pyruvate oxidase sensor , 1980 .