Joint ToF Image Denoising and Registration with a CT Surface in Radiation Therapy

The management of intra-fractional respiratory motion is becoming increasingly important in radiation therapy. Based on in advance acquired accurate 3D CT data and intra-fractionally recorded noisy time-of-flight (ToF) range data an improved treatment can be achieved. In this paper, a variational approach for the joint registration of the thorax surface extracted from a CT and a ToF image and the denoising of the ToF image is proposed. This enables a robust intra-fractional full torso surface acquisition and deformation tracking to cope with variations in patient pose and respiratory motion. Thereby, the aim is to improve radiotherapy for patients with thoracic, abdominal and pelvic tumors. The approach combines a Huber norm type regularization of the ToF data and a geometrically consistent treatment of the shape mismatch. The algorithm is tested and validated on synthetic and real ToF/CT data and then evaluated on real ToF data and 4D CT phantom experiments.

[1]  C. Deehan,et al.  Real time 3D surface imaging for the analysis of respiratory motion during radiotherapy , 2004 .

[2]  J. Hornegger,et al.  Time-of-flight sensor for respiratory motion gating. , 2008, Medical physics.

[3]  Martin Rumpf,et al.  Multiscale Joint Segmentation and Registration of Image Morphology , 2007, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  Ali Mohammad-Djafari,et al.  Image fusion and unsupervised joint segmentation using a HMM and MCMC algorithms , 2005, J. Electronic Imaging.

[5]  C. L. Le Rest,et al.  A patient specific respiratory model based on 4D CT data and a time of flight camera (TOF) , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[6]  J. McClelland,et al.  A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. , 2006, Medical physics.

[7]  Reinhard Koch,et al.  Time-of-Flight Sensors in Computer Graphics , 2009, Eurographics.

[8]  Joachim Hornegger,et al.  Time-of-Flight sensor for patient positioning , 2009, Medical Imaging.

[9]  A. Norman,et al.  Accuracy of set-up of thoracic radiotherapy: prospective analysis of 24 patients treated with radiotherapy for lung cancer. , 2002, The British journal of radiology.

[10]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[11]  Tinsu Pan,et al.  A 2D-spline patient specific model for use in radiation therapy , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[12]  Reinhard Koch,et al.  Time-of-Flight sensor calibration for accurate range sensing , 2010, Comput. Vis. Image Underst..

[13]  V. Peters,et al.  A Simulation Framework for Time-Of-Flight Sensors , 2007, 2007 International Symposium on Signals, Circuits and Systems.

[14]  Yifei Lou,et al.  A note on multi-image denoising , 2009, 2009 International Workshop on Local and Non-Local Approximation in Image Processing.

[15]  L. Armijo Minimization of functions having Lipschitz continuous first partial derivatives. , 1966 .

[16]  A. Yezzi,et al.  A variational framework for joint segmentation and registration , 2001, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 2001).

[17]  Joachim Weickert,et al.  Scale-Space Theories in Computer Vision , 1999, Lecture Notes in Computer Science.

[18]  P. Smereka,et al.  A Remark on Computing Distance Functions , 2000 .

[19]  Joachim Weickert,et al.  A Scale-Space Approach to Nonlocal Optical Flow Calculations , 1999, Scale-Space.