Analysis of Valveless Piezoelectric Micropump using Electrical Equivalent Circuit Model

An improved equivalent circuit model for effective calculation of a valveless piezoelectric micropump performance which is operated by a dependency of flow resistance on flow rate was proposed. The validity of the proposed model was evaluated by comparing the dynamic flow behavior calculated by the equivalent circuit model with mu-PIV measurement. From the good agreements between the analysis and the experimental results, it was concluded that a dynamic flow characteristic with microsecond scale of the micropump was able to be analyzed precisely by the developed equivalent circuit model.

[1]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[2]  Shunichi Hayamizu,et al.  Development of a bi-directional valve-less silicon micro pump controlled by driving waveform , 2003 .

[3]  John L. Crassidis,et al.  Sensors and actuators , 2005, Conference on Electron Devices, 2005 Spanish.

[4]  G. Stemme,et al.  A valveless diffuser/nozzle-based fluid pump , 1993 .