Development of Non-destructive Assay System using Fast Neutron Direct Interrogation Method for Actual Uranium Waste Drums

A non-destructive assay system using the fast neutron direct interrogation method has been de-signed and developed to be put into practical use for the determination of the uranium ( 235 U ) mass contained in actual uranium-contaminated waste drums. The method is capable of measuring the fissile mass in a drum by counting the number of fission neutrons resulting from nuclear fission reac-tions between the fissile materials contained in a drum and thermal neutrons generated by 14 MeV fast neutrons irradiated from outside the drum. A performance test employing simulated metal waste drums demonstrated that a natural uranium mass of as low as approximately 10 g could be detected within an error of ± 20 % regardless of the distribution of uranium samples in the drum, and the total number of fission neutrons was proportional to the 235 U mass. A demonstration test employing actual waste drums could determine the uranium mass by using a newly developed correction method for de-riving the fissile mass in a drum. It has been proved by the experimental validation tests that the assay system equipped with the correction method is very useful for the accountancy of waste drums.

[1]  薫 横山,et al.  CANBERRA製Qualitative and Quantative(Q2)装置による廃棄物ドラム缶中のウラン放射能定量試験 , 2013 .

[2]  Yasuo Suzuki,et al.  Verification Tests on Nondestructive Assay for 238U Content in Uranium-contaminated Waste Drums Using Gamma Method , 2013 .

[3]  Naoki Zaima,et al.  On Performance Experience and Measurements with Ningyo Waste Assay System ( NWAS )-II , 2012 .

[4]  E. Brackx,et al.  Application of active and passive neutron non destructive assay methods to concrete radioactive waste drums , 2011 .

[5]  M. Takase High-Sensitivity Detection of Fissile Materials in a Waste Dram by Direct Interrogation of 14 MeV Acc Neutrons , 2009 .

[6]  M. Haruyama,et al.  Improvement of Detection Limit in 14MeV Neutron Direct Interrogation Method by Decreasing Background , 2008 .

[7]  A. Favalli,et al.  Design and characterisation of a pulsed neutron interrogation facility. , 2007, Radiation protection dosimetry.

[8]  Takamasa Mori,et al.  High-Sensitive Detection by Direct Interrogation of 14 MeV Acc Neutrons, (II) Uranium-Contained Cloth Matrix in a Waste Dram , 2007 .

[9]  A. Lyoussi,et al.  Transuranic waste assay by neutron interrogation and online prompt and delayed neutron measurement , 2003 .

[10]  Katsuyuki Ara,et al.  High-Sensitivity Detection of Fissile Materials in a Waste Dram by Direct Interrogation of 14MeV Acc Neutrons. , 2001 .

[11]  J. T. Caldwell,et al.  A l-nCi/g sensitivity transuranic waste assay system using pulsed neutron interrogation , 1980 .