Asymmetric time-dependent model for the dynamic finger arterial pressure–volume relationship

The volumetric pulses in the finger PPG signal appear as an information source for several indirect measurement methods. In this study we modelled transformation of pressure pulses into volume pulses in a wide transmural pressure range. The noninvasive finger arterial pressure and photoplethysmographic (PPG) signals were simultaneously registered in 13 healthy subjects while the pressure in the PPG cuff ramped up and down. The nonlinearity of the pressure–volume (P–V) relationship was modelled by an asymmetric function, consisting of two arctangents, each for a different pressure region. The time dependency was described by the first order lag. The disturbing effect of slow creeps in the PPG signal was suppressed by an equal filtering of the measured and model-predicted signal. The differences between the two estimates of the subject’s P–V relationship for the increasing and decreasing cuff pressure were small thus showing the repeatability of this method, which can be used for the characterization of individual finger arterial behaviour as well as its changes.

[1]  Y. Mendelson Pulse oximetry: theory and applications for noninvasive monitoring. , 1992, Clinical chemistry.

[2]  Kirk H. Shelley,et al.  Arterial–Pulse Oximetry Loops: A New Method of Monitoring Vascular Tone , 1997, Journal of Clinical Monitoring.

[3]  P. Jurák,et al.  Vibration plethysmography: A method for studying the visco-elastic properties of finger arteries , 1997, Medical and Biological Engineering and Computing.

[4]  M. Nitzan,et al.  The difference in pulse transit time to the toe and finger measured by photoplethysmography. , 2002, Physiological measurement.

[5]  J. J. Settels,et al.  Physiocal, calibrating finger vascular physiology for finapres , 1995 .

[6]  G. Mancia,et al.  Progression of large artery structural and functional alterations in Type I diabetes , 2001, Diabetologia.

[7]  S N Hunyor,et al.  Continuous, non-invasive volume-clamp blood pressure: determinants of performance , 1993, Journal of hypertension.

[8]  P. Chowienczyk,et al.  Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse , 2000, Hypertension.

[9]  G. Drzewiecki,et al.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios , 2006, Annals of Biomedical Engineering.

[10]  J. Talts,et al.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion , 1999, Medical & Biological Engineering & Computing.

[11]  A. Pasipoularides,et al.  Right ventricular diastolic function in canine models of pressure overload, volume overload, and ischemia. , 2002, American journal of physiology. Heart and circulatory physiology.

[12]  Patrick Segers,et al.  Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters model. , 2005, American journal of physiology. Heart and circulatory physiology.

[13]  G. Langewouters,et al.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. , 1984, Journal of biomechanics.

[14]  A. Murray,et al.  Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques , 1999, Physiological measurement.

[15]  A. Bank,et al.  Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus. , 1996, Circulation.

[16]  A. Bank,et al.  In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation. , 1999, Circulation.

[17]  Yukihiro Sawada,et al.  Finger arterial compliance as determined by transmission of light during mental stress and reactive hyperaemia , 2002, European Journal of Applied Physiology.

[18]  K. Wesseling,et al.  Forearm arterial pressure-volume relationships in man. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[19]  G Parati,et al.  Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording. , 1993, Hypertension.

[20]  D. Westenskow,et al.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure , 1997, Medical and Biological Engineering and Computing.

[21]  A. Buchs,et al.  Right-left correlation of the sympathetically induced fluctuations of photoplethysmographic signal in diabetic and non-diabetic subjects , 2006, Medical and Biological Engineering and Computing.