Design and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results

Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolic velocity and resistive index, i.e., 131.49 ± 3.97 and 0.75 ± 0.02 vs. 131.89 ± 2.06 and 0.74 ± 0.02, respectively. In addition, in the in vivo study, the neckband Doppler system successfully demonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicate that the developed wireless neckband Doppler system can be used for continuous monitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.

[1]  R S Cobbold,et al.  A comparative study and assessment of Doppler ultrasound spectral estimation techniques. Part I: Estimation methods. , 1988, Ultrasound in medicine & biology.

[2]  D. Schellinger,et al.  Duplex carotid sonography: criteria for stenosis, accuracy, and pitfalls. , 1985, Radiology.

[3]  Y. Yonekawa,et al.  Noninvasive Angiography for the Diagnosis of Carotid Artery Disease Using Doppler Ultrasound (Carotid Artery Doppler) , 1976, Stroke.

[4]  R. Aaslid,et al.  Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound. , 1985, Journal of neurosurgery.

[5]  S. Pitner Carotid thrombosis due to intraoral trauma. An unusual complication of a common childhood accident. , 1966, The New England journal of medicine.

[6]  J. U. Quistgaard,et al.  Signal acquisition and processing in medical diagnostic ultrasound , 1997, IEEE Signal Process. Mag..

[7]  S. Holland,et al.  Doppler US. Part I. Basic principles, instrumentation, and pitfalls. , 1990, Radiology.

[8]  D. Taggart,et al.  Coronary artery bypass grafting for left main disease and the risk of stroke: Incidence, aetiology and prevention. , 2017, The surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland.

[9]  M Kassam,et al.  A critical study of ultrasound Doppler spectral analysis for detecting carotid disease. , 1982, Ultrasound in medicine & biology.

[10]  J. Norris,et al.  Carotid Doppler evaluation in cerebrovascular disease. , 1983, Canadian Medical Association journal.

[11]  N L Browse,et al.  Transcranial Doppler measurement of middle cerebral artery blood flow velocity: a validation study. , 1986, Stroke.

[12]  J M Rubin,et al.  Relationship between the resistive index and vascular compliance and resistance. , 1999, Radiology.

[13]  R. Schneider,et al.  Traumatic internal carotid artery thrombosis secondary to nonpenetrating injuries to the neck; a problem in the differential diagnosis of craniocerebral trauma. , 1952, Journal of neurosurgery.

[14]  J. Murie,et al.  Ultrasonic doppler spectral broadening in the diagnosis of internal carotid artery stenosis. , 1983, Ultrasound in medicine & biology.

[15]  E. Awad,et al.  The Doppler Necklace: a wearable and noninvasive ultrasound sensor for continuous monitoring of blood flow in the common carotid artery , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[16]  A. Strano,et al.  Incidence of Carotid Artery Atherosclerosis in Patients with Coronary Artery Disease , 1993, Angiology.

[17]  D. Staub,et al.  Comparison of Carotid Arterial Resistive Indices With Intima-Media Thickness as Sonographic Markers of Atherosclerosis , 2001, Stroke.

[18]  B. Carroll,et al.  Duplex ultrasound scanning of the carotid arteries with velocity spectrum analysis. , 1983, Radiology.

[19]  Guang Deng,et al.  A Generalized Unsharp Masking Algorithm , 2011, IEEE Transactions on Image Processing.

[20]  D. Staub,et al.  Prediction of Cardiovascular Morbidity and Mortality: Comparison of the Internal Carotid Artery Resistive Index With the Common Carotid Artery Intima-Media Thickness , 2006, Stroke.

[21]  M. Teixeira,et al.  Cerebral hemodynamic changes gauged by transcranial Doppler ultrasonography in patients with posttraumatic brain swelling treated by surgical decompression. , 2006, Journal of neurosurgery.

[22]  K. Johnston,et al.  Cerebrovascular assessment using a doppler carotid scanner and real‐time frequency analysis , 1981, Journal of clinical ultrasound : JCU.

[23]  R S Cobbold,et al.  A comparative study and assessment of Doppler ultrasound spectral estimation techniques. Part II: Methods and results. , 1988, Ultrasound in medicine & biology.

[24]  S. Tomita,et al.  The Prevalence and Distribution of Occlusive Lesions of the Cerebral Arteries in Patients Undergoing Coronary Artery Bypass Graft Surgery. , 2018, Seminars in thoracic and cardiovascular surgery.

[25]  Chih-Chung Huang,et al.  Design and implementation of a smartphone-based portable ultrasound pulsed-wave doppler device for blood flow measurement , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.