Evanescent wave biosensors

Optical biosensors, based on evanescent wave technology, are analytical devices that measure the interactions between biomolecules in real time, without the need for any labels. Specific ligands are immobilized to a sensor surface, and a solution of receptor or antibody is injected over the top. Binding is measured by recording changes in the refractive index, caused by the molecules interacting near the sensor surface within the evanescent field. Evanescent wave-based biosensors are being used to study an increasing number of applications in the life sciences, including the binding and dissociation kinetics of antibodies and receptor-ligand pairs, protein-DNA and DNA-DNA interactions, epitope mapping, phage display libraries, and whole cell- and virus-protein interactions. There are currently four commercially available avanescent wave biosensors on the market. This article describes the technology behind their sensing techniques, as well as the range of applications in which they are employed.

[1]  M. Thompson,et al.  Biosensors and the transduction of molecular recognition. , 1991, Analytical chemistry.

[2]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[3]  B. Persson,et al.  Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins , 1991 .

[4]  J. Wells,et al.  Comparison of a structural and a functional epitope. , 1993, Journal of molecular biology.

[5]  A. Barclay,et al.  Affinity and kinetic analysis of the interaction of the cell adhesion molecules rat CD2 and CD48. , 1993, The EMBO journal.

[6]  D. O'Shannessy,et al.  Detection of receptor-ligand interactions using surface plasmon resonance: model studies employing the HIV-1 gp120/CD4 interaction. , 1992, Analytical biochemistry.

[7]  Stephan C. Schuster,et al.  Assembly and function of a quaternary signal transduction complex monitored by surface plasmon resonance , 1993, Nature.

[8]  Y Hasegawa,et al.  Kinetic measurement of the interaction between an oligosaccharide and lectins by a biosensor based on surface plasmon resonance. , 1994, European journal of biochemistry.

[9]  U Wollenberger,et al.  Research and development of biosensors. A review. , 1989, The Analyst.

[10]  S. Wood DNA-DNA Hybridization in Real Time Using BIAcore , 1993 .

[11]  J. Erickson,et al.  Real‐time DNA binding measurements of the ETSl recombinant oncoproteins reveal significant kinetic differences between the p42 and p51 isoforms , 1994, Protein science : a publication of the Protein Society.

[12]  Japan — Biosensor used to measure interaction between an oligosaccharide and lectins , 1995 .

[13]  J. McVey,et al.  Surface plasmon resonance studies of the interaction between factor VII and tissue factor. Demonstration of defective tissue factor binding in a variant FVII molecule (FVII-R79Q). , 1994, Biochemistry.

[14]  M. Kasuga,et al.  A biosensor approach to probe the structure and function of the p85 alpha subunit of the phosphatidylinositol 3-kinase complex. , 1993, The Journal of biological chemistry.

[15]  J. Cronin,et al.  The resonant mirror: a novel optical biosensor for direct sensing of biomolecular interactions Part I: Principle of operation and associated instrumentation , 1992 .

[16]  R. Karlsson,et al.  Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system. , 1991, Journal of immunological methods.

[17]  R. Karlsson,et al.  Real-time biospecific interaction analysis using surface plasmon resonance and a sensor chip technology. , 1991, BioTechniques.

[18]  M. Moo-young,et al.  Biosensors: recent trends. , 1985, Biotechnology advances.

[19]  R. Karlsson,et al.  Detection of antigen—antibody interactions by surface plasmon resonance. Application to Epitope Mapping , 1990, Journal of molecular recognition : JMR.

[20]  D. Altschuh,et al.  Interaction between viruses and monoclonal antibodies studied by surface plasmon resonance. , 1992, Immunology letters.

[21]  P. Nellen,et al.  Output grating couplers on planar optical waveguides as direct immunosensors. , 1991, Biosensors & bioelectronics.

[22]  Pankaj Vadgama,et al.  Biosensors: recent trends. A review , 1992 .

[23]  T Prospero,et al.  "Diabodies": small bivalent and bispecific antibody fragments. , 1993, Proceedings of the National Academy of Sciences of the United States of America.

[24]  A. Knoll,et al.  End of the Proterozoic eon. , 1991, Scientific American.

[25]  A. Hutchinson Characterization of glycoprotein oligosaccharides using surface plasmon resonance. , 1994, Analytical biochemistry.

[26]  Eskil Söderlind,et al.  Phage Display Technology in Antibody Engineering: Design of Phagemid Vectors and in vitro Maturation Systems , 1992, Immunological reviews.

[27]  M. Gadnell,et al.  Epitope mapping and binding kinetics of monoclonal antibodies studied by real time biospecific interaction analysis using surface plasmon resonance. , 1993, Journal of immunological methods.

[28]  D. O'Shannessy,et al.  A micro-scale method employing surface plasmon resonance detection for the determination of conditions for immunoaffinity chromatography of proteins , 1993 .