Partial discharge measurement at DC voltage — Evaluation and characterization by NoDi∗ pattern

In this paper the requirements on PD measurement systems for DC voltage are summarized and the experience gained about the PD behavior of some typical defects in HVDC GIS and GIL are discussed. Some physical effects at different voltage levels are shown and a method for the representation and characterization of the PD pulse sequences is introduced. Special test cells with different types of defects such as a protrusion, a floating electrode, a free moving particle and a void are used for the investigations. The procedure for PD measurement at DC voltage is improved and PD pulse sequences at different gas pressures and voltage levels were recorded. In a further step the PD behavior up to the breakdown voltage was determined. The NoDi∗ pattern was developed for the visualization and interpretation of the measured PD pulse sequences. This pattern supports the visualization and the physical interpretation of the pulse sequences and may allow the characterization of the typical defects in HVDC GIS and GIL by a human expert.

[1]  T. Hinterholzer Space-charge-stabilization in SF6 , 2001 .

[2]  P.H.F. Morshuis,et al.  Classification of partial discharges for DC equipment , 1996, Proceedings of Conference on Electrical Insulation and Dielectric Phenomena - CEIDP '96.

[3]  J. Suehiro,et al.  DC corona discharge from floating particle in low pressure SF/sub 6/ , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  P.H.F. Morshuis,et al.  Partial discharge. Part XXIV: The analysis of PD in HVDC equipment , 1997 .

[5]  Shigemitsu Okabe,et al.  Space charge behaviour and corona stabilization effect in SF6gas viewed from sequential generation of a dc partial discharge , 2001 .

[6]  van Em Eddie Veldhuizen,et al.  Corona discharges: fundamentals and diagnostics , 2001 .

[7]  U. Hammer,et al.  Evaluation and limitations of corona discharge measurements - an application point of view , 2016, 2016 International Conference on Condition Monitoring and Diagnosis (CMD).

[8]  C. Cooke,et al.  Influence of particles on AC and DC electrical performance of gas insulated systems at extra-high-voltage , 1977, IEEE Transactions on Power Apparatus and Systems.

[9]  P. Morshuis,et al.  Partial discharges at DC voltage: their mechanism, detection and analysis , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Bernd Freisleben,et al.  PD source identification with novel discharge parameters using counterpropagation neural networks , 1997 .

[11]  A. A. A-Rahim,et al.  Dynamic analysis of motion of spherical metallic particles in non-uniform electric field , 2002 .

[12]  Ja-Yoon Koo,et al.  Neural network based diagnosis of partial discharge defects patterns at XLPE cable under DC stress , 2017 .

[13]  B. W. Lee,et al.  Identification of Insulation Defects by modified Chaotic Analysis of Partial Discharge under DC Stress , 2012 .

[14]  G. Montanari,et al.  Partial discharge analysis and monitoring in HVDC gas insulated substations , 2014, 2014 IEEE Electrical Insulation Conference (EIC).

[15]  Guangning Wu,et al.  Partial discharge pulse shape detection and analysis under DC condition in typical defect models , 2007, 2007 Annual Report - Conference on Electrical Insulation and Dielectric Phenomena.

[16]  F. Jenau,et al.  Evaluation of surface- and corona discharges at DC voltage , 2013, 2013 13th International Conference on Environment and Electrical Engineering (EEEIC).

[17]  M. Vakilian,et al.  DC partial discharge characteristics for corona, surface and void discharges , 2015, 2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM).

[18]  Alexander Pirker,et al.  PD Measurement at DC Voltage on typical Defects of GIS/GIL , 2015 .

[19]  E. Lemke,et al.  Using a field probe to study the mechanism of partial discharges in very small air gaps under direct voltage , 2016, IEEE Electrical Insulation Magazine.

[20]  K. Nojima,et al.  Forces affecting metallic particle motion in GIS , 2014, Proceedings of 2014 International Symposium on Electrical Insulating Materials.

[21]  Dietmar Retzmann,et al.  State of the Art in Ultrahigh-Voltage Transmission , 2012, Proceedings of the IEEE.

[22]  Chaotic Characteristic of Time Series of Partial Discharge in Oil-Paper Insulation , 2011 .

[23]  Pavel Trnka,et al.  Pulse sequence analysis of corona discharge at DC voltage , 2016, 2016 Diagnostic of Electrical Machines and Insulating Systems in Electrical Engineering (DEMISEE).

[25]  A Cavallini,et al.  Diagnostic of HVDC systems using partial discharges , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[26]  Li Yanming,et al.  Digital detection, grouping and classification of partial discharge signals at DC voltage , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[27]  Alain Girodet,et al.  Partial discharge analysis of gas insulated systems at high voltage AC and DC , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[28]  Paul Lewin,et al.  Wavelet packet denoising for online partial discharge detection in cables and its application to experimental field results , 2006 .