Automated detection of rotor faults for inverter-fed induction machines under standstill conditions

It is difficult to apply conventional on-line MCSA techniques for diagnosis of rotor faults for closed loop induction motor drives for many applications due to the masking effect of the feedback current controller and/or variable frequency or load operation. Relying solely on traditional off-line inspection techniques during regular maintenance does not allow frequent monitoring of rotor problems and is inconvenient since it requires rotor disassembly and/or manual rotor rotation. In this paper, a new automated technique for testing inverter-fed squirrel cage induction machines at standstill for rotor faults is proposed. The main concept is to use the inverter to excite the machine with a pulsating field at a number of angular positions to observe the variation in the impedance pattern due to broken rotor bars, whenever the motor is stopped. An experimental study on a 7.5hp induction motor verifies that broken bars can be detected with high sensitivity and reliability. It will be shown that the proposed method can provide automated and reliable assessment of rotor condition frequently without motor disassembly, manual rotation, or additional instrumentation. The proposed test can also provide rotor quality assessment independent of variations in motor or load operating conditions since it is a standstill test.

[1]  António J. Marques Cardoso,et al.  A New Model-Based Technique for the Diagnosis of Rotor Faults in RFOC Induction Motor Drives , 2008, IEEE Transactions on Industrial Electronics.

[2]  M. W. Degner,et al.  On-line diagnostics in inverter fed induction machines using high frequency signal injection , 2003 .

[3]  Gérard-André Capolino,et al.  Advances in Diagnostic Techniques for Induction Machines , 2008, IEEE Transactions on Industrial Electronics.

[4]  Josep M. Guerrero,et al.  Online diagnostics in inverter-fed induction machines using high-frequency signal injection , 2004, IEEE Transactions on Industry Applications.

[5]  F. Filippetti,et al.  Closed loop control impact on the diagnosis of induction motors faults , 1999 .

[6]  G. B. Kliman,et al.  Noninvasive detection of broken rotor bars in operating induction motors , 1988 .

[7]  C. F. Landy,et al.  The Existence of Large Inter-Bar Currents in Three Phase Squirrel Cage Motors with Rotor-Bar And/Or End-Ring Faults , 1984 .

[8]  H. Henao,et al.  Detection of induction machines rotor faults at standstill using signals injection , 2004, IEEE Transactions on Industry Applications.

[9]  I. Kerszenbaum,et al.  The Existence of Large Inter-Bar Currents in Three Phase Squirrel Cage Motors with Rotor-Bar And/Or End-Ring Faults , 1984, IEEE Transactions on Power Apparatus and Systems.

[10]  Behrooz Mirafzal,et al.  Induction machine broken-bar fault diagnosis using the rotor magnetic field space-vector orientation , 2004 .

[11]  H.A. Toliyat,et al.  Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review , 2005, IEEE Transactions on Energy Conversion.

[12]  William R. Finley,et al.  Selection of copper vs. aluminum rotors for induction motors , 2000, Record of Conference Papers. Industry Applications Society Forty-Seventh Annual Conference. 2000 Petroleum and Chemical Industry Technical Conference (Cat. No.00CH37112).

[13]  Christian Kral,et al.  Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-the Vienna Monitoring Method , 1998, IEEE Trans. Ind. Electron..

[14]  Austin H. Bonnett,et al.  Rotor Failures in Squirrel Cage Induction Motors , 1986, IEEE Transactions on Industry Applications.

[15]  A.J.M. Cardoso,et al.  Diagnosis of Rotor Faults in Closed-Loop Induction Motor Drives , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[16]  D. Leith,et al.  Real time expert system for identifying rotor faults and mechanical influences in induction motor phase current , 1991 .

[17]  A.H. Bonnett,et al.  Squirrel cage rotor options for AC induction motors , 2000, Conference Record of 2000 Annual Pulp and Paper Industry Technical Conference (Cat. No.00CH37111).

[18]  C. Kral,et al.  Detection of rotor faults in squirrel cage induction machines at standstill for batch tests by means of the Vienna monitoring method , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[19]  G. Stone,et al.  Electrical Insulation for Rotating Machines , 2003 .

[20]  Hamid A. Toliyat,et al.  Handbook of Electric Motors , 2004 .

[21]  D.L. McKinnon Using a six fault zone approach for predictive maintenance on motors , 2007, 2007 Electrical Insulation Conference and Electrical Manufacturing Expo.

[22]  Hamid A. Toliyat,et al.  DSP-Based Sensorless Electric Motor Fault Diagnosis Tools for Electric and Hybrid Electric Vehicle Powertrain Applications , 2009, IEEE Transactions on Vehicular Technology.