Locking compression plate stabilization of 20 distal radial and ulnar fractures in toy and miniature breed dogs

Summary Objective: To evaluate retrospectively the effectiveness of the Locking Compression Plate® (LCP), in the form of either a straight or notched head T-plate, for the treatment of fractures of the distal radius and ulna in a series of 20 toy and miniature breed dogs. Methods: The medical records of toy and miniature breed dogs (<6 kg), greater than six months of age, with fractures of the distal radius and ulna from two veterinary hospitals were reviewed. The inclusion criteria included: fractures of the distal 1/3 of the radius and ulna and repair with open reduction and internal fixation utilizing an LCP (straight or notched head T-plate). Results: Twenty fractures (20 dogs) satisfied the inclusion criteria; eight straight and 12 notched head T-plates were used, either 2.0 mm (n = 13) or 2.4 mm (n = 7). Hybrid fixation was performed in all dogs in one or both fragments. Mean time to radiographic union was 6.9 ± 2.5 weeks (range: 4–12 weeks) in 18/20 dogs with radiographic follow-up. One complication was observed: infection that resolved with antibiotic medication and implant removal. No other major complications occurred by the time of last follow-up. In all cases (mean follow-up: 15 ± 7 months), the reported limb function as evaluated by the referring veterinarian or owner was excellent. Clinical significance: The LCP, used as a hybrid construct for the treatment of distal radial and ulnar fractures was shown to yield excellent clinical results with both uncomplicated healing and excellent functional outcomes in this series of toy and miniature breed dogs.

[1]  C. Decamp 2 – Fractures: Classification, diagnosis, and treatment , 2016 .

[2]  S. Nemanic,et al.  Augmentation of diaphyseal fractures of the radius and ulna in toy breed dogs using a free autogenous omental graft and bone plating , 2015, Veterinary and Comparative Orthopaedics and Traumatology.

[3]  B. Beale,et al.  Outcome following removal of TPLO implants with surgical site infection , 2013, Veterinary and Comparative Orthopaedics and Traumatology.

[4]  K. Wells,et al.  Tibial plateau levelling osteotomy implant removal: A retrospective analysis of 129 cases , 2011, Veterinary and comparative orthopaedics and traumatology.

[5]  A. Ferretti,et al.  Treatment of fractures of the distal radius and ulna in toy breed dogs with circular external skeletal fixation: a retrospective study , 2011, Veterinary and Comparative Orthopaedics and Traumatology.

[6]  M. Bottlang,et al.  Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis. , 2010, The Journal of trauma.

[7]  W. McCartney,et al.  Treatment of distal radial/ulnar fractures in 17 toy breed dogs , 2010, Veterinary Record.

[8]  M. Kull',et al.  Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system , 2009, Veterinary and Comparative Orthopaedics and Traumatology.

[9]  R. M. Greiwe,et al.  Locking Plate Technology – Current Concepts , 2010, The journal of knee surgery.

[10]  P. Botti,et al.  Cross-sectional geometrical properties of distal radius and ulna in large, medium and toy breed dogs. , 2006, Journal of biomechanics.

[11]  M. Hamilton,et al.  Use of the AO veterinary mini ‘T’-plate for stabilisation of distal radius and ulna fractures in toy breed dogs , 2005, Veterinary and Comparative Orthopaedics and Traumatology.

[12]  Ann L. Johnson,et al.  AO Principles of Fracture Management in the Dog and Cat , 2005 .

[13]  Michael J Gardner,et al.  Has locked plating completely replaced conventional plating? , 2004, American journal of orthopedics.

[14]  M. Wagner,et al.  General principles for the clinical use of the LCP. , 2003, Injury.

[15]  Ulrich Dieter,et al.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? , 2003, Injury.

[16]  S. Perren Backgrounds of the technology of internal fixators. , 2003, Injury.

[17]  P. Montavon,et al.  Use of the tubular external fixator in the treatment of distal radial and ulnar fractures in small dogs and cats , 2003, Veterinary and Comparative Orthopaedics and Traumatology.

[18]  J. Roush,et al.  Bone plate fixation of distal radius and ulna fractures in small- and miniature-breed dogs. , 1999, Journal of the American Animal Hospital Association.

[19]  J. Field Bone Plate Fixation: Its Relationship with Implant Induced Osteoporosis , 1997, Veterinary and Comparative Orthopaedics and Traumatology.

[20]  G. Spodnick,et al.  The intraosseous blood supply of the canine radius: implications for healing of distal fractures in small dogs. , 1997, Veterinary surgery : VS.

[21]  M. Markel,et al.  Geometric variables and bone mineral density as potential predictors for mechanical properties of the radius of Greyhounds. , 1996, American journal of veterinary research.

[22]  D M Nunamaker,et al.  Contact area and static pressure profile at the plate-bone interface in the nonluted and luted bone plate. , 1995, Veterinary surgery : VS.

[23]  G. Breur,et al.  Treatment of common forelimb fractures in miniature- and toy-breed dogs , 1993 .

[24]  G. Bacci,et al.  The effect of chemoterapy on uncemented prostheic replacement , 1991 .

[25]  C. E. Eger A technique for the management of radial and ulnar fractures in miniature dogs using translation pins , 1990 .

[26]  H. Herron,et al.  Fractures of the radius and ulna in the dog , 1983 .

[27]  S. G. Brown,et al.  Fixation of Radius and Ulna Fractures in the Immature Dog and Cat A Review of Popular Techniques and a Report of Eight Cases Using Plate Fixation , 1982 .

[28]  C. Gibbs,et al.  The complications of diaphyseal fractures in dogs: a review of 100 cases. , 1980, The Journal of small animal practice.

[29]  G. Sumner-Smith A histological study of fracture nonunion in small dogs. , 1974, The Journal of small animal practice.

[30]  G. Sumner-Smith A comparative investigation into the healing of fractures in miniature poodles and mongrel dogs. , 1974, The Journal of small animal practice.

[31]  L. Vaughan A Clinical Study of Non‐union Fractures in the Dog* , 1964 .