The analysis and counting of blood cells in a microscope image can provide useful information concerning to the health of a person. In particular, morphological analysis of red blood cell’s deformations can effectively detect important disease like malaria. Blood images, obtained by the microscope, which is coupled with a digital camera, are analyzed by the computer for diagnosis or can be transmitted easily to clinical centers than liquid blood samples. Automatic analysis system for the presence of Plasmodium in microscopic image of blood can greatly help pathologists and doctors that typically inspect blood films manually. Unfortunately, the analysis made by human experts is not rapid and not yet standardized due to the operators’ capabilities and tiredness. The paper shows how effectively and accurately it is possible to identify the Plasmodium in the blood film. In particular, the paper presents how to enhance the microscopic image and filter out the unnecessary segments followed by the threshold based segmentation and recognize the presence of Plasmodium. The proposed system can be deployed in the remote area as a supporting aid for telemedicine technology and only basic training is sufficient to operate it. This system achieved more than 98% accuracy for the samples collected to test this system.
[1] Rafael C. González,et al. Digital image processing using MATLAB , 2006 .
[2] Mita Nasipuri,et al. Round-the-clock urine sugar monitoring system for diabetic patients , 2010, 2010 International Conference on Systems in Medicine and Biology.
[3] Leszek Wojnar,et al. Image Analysis , 1998 .
[4] Stephen E. Holland. Fully Depleted Charge-Coupled Devices , 2006 .