Spatial Intensity Correction of Fluorescent Confocal Laser Scanning Microscope Images

Fluorescent confocal laser scanning microscope (CLSM) imaging has become popular in medical domain for the purpose of 3D information extraction. 3D information is extracted either by visual inspection or by automated techniques. Nonetheless, 3D information extraction from CLSM suffers from significant lateral intensity heterogeneity. We propose a novel lateral intensity heterogeneity correction technique to improve accurate image analysis, e.g., quantitative analysis, segmentation, or visualization. The proposed technique is novel in terms of its design (spatially adaptive mean-weight filtering) and application (CLSM), as well as its properties and full automation. The key properties of the intensity correction techniques include adjustment of intensity heterogeneity, preservation of fine structural details, and enhancement of image contrast. The full automation is achieved by data-driven parameter optimization and introduction of several evaluation metrics. We evaluated the performance by comparing with three other techniques, four quality metrics, and two realistic synthetic images and one real CLSM image.

[1]  P. Oostveldt,et al.  Heterogeneous photobleaching in confocal microscopy caused by differences in refractive index and excitation mode. , 1998, Cytometry.

[2]  P. Groves,et al.  Methodology For Hyperspectral Band Selection , 2004 .

[3]  J. Vassy,et al.  High-resolution three-dimensional images from confocal scanning laser microscopy. Quantitative study and mathematical correction of the effects from bleaching and fluorescence attenuation in depth. , 1991, Analytical and quantitative cytology and histology.

[4]  K. Rodenacker,et al.  Groping for Quantitative Digital 3-D Image Analysis: An Approach to Quantitative Fluorescence In Situ Hybridization in Thick Tissue Sections of Prostate Carcinoma , 1997, Analytical cellular pathology : the journal of the European Society for Analytical Cellular Pathology.

[5]  D M Benson,et al.  Digital imaging fluorescence microscopy: spatial heterogeneity of photobleaching rate constants in individual cells , 1985, The Journal of cell biology.

[6]  W. von Seelen,et al.  A System for the Diagnostic Use of Tissue Characterizing Parameters in N M R — Tomography , 1988 .

[7]  Eusebio Bernabeu,et al.  On the standard deviation in charge-coupled device cameras: A variogram-based technique for nonuniform images , 2002, J. Electronic Imaging.

[8]  Anshuman Razdan,et al.  Volumetric Segmentation Using Weibull E-SD Fields , 2003, IEEE Trans. Vis. Comput. Graph..

[9]  J. Mangin,et al.  Entropy minimization for automatic correction of intensity nonuniformity , 2000, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis. MMBIA-2000 (Cat. No.PR00737).

[10]  Loretta Auvil,et al.  Three-dimensional reconstruction of extravascular matrix patterns and blood vessels in human uveal melanoma tissue: techniques and preliminary findings. , 2003, Investigative ophthalmology & visual science.

[11]  C. Kervrann,et al.  Robust incremental compensation of the light attenuation with depth in 3D fluorescence microscopy , 2004, Journal of microscopy.

[12]  A Liljeborg,et al.  A method to compensate for light attenuation with depth in three‐dimensional DNA image cytometry using a confocal scanning laser microscope , 1995, Journal of microscopy.

[13]  J P Rigaut,et al.  Three-dimensional DNA image cytometry by confocal scanning laser microscopy in thick tissue blocks of prostatic lesions. , 1997, Cytometry.

[14]  S. Pizer,et al.  Adaptive grey level assignment in CT scan display. , 1984, Journal of computer assisted tomography.

[15]  Jos B. T. M. Roerdink,et al.  An FFT‐based method for attenuation correction in fluorescence confocal microscopy , 1993 .

[16]  Martin Styner,et al.  Parametric estimate of intensity inhomogeneities applied to MRI , 2000, IEEE Transactions on Medical Imaging.