The shielding at an accelerator-driven spallation neutron facility plays a critical role in the performance of the neutron scattering instruments, the overall safety, and the total cost of the facility. Accurate simulation of shielding components is thus key for the design of upcoming facilities, such as the European Spallation Source (ESS), currently in construction in Lund, Sweden. In this paper, we present a comparative study between the measured and the simulated neutron background at the Swiss Spallation Neutron Source (SINQ), at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The measurements were carried out at several positions along the SINQ monolith wall with the neutron dosimeter WENDI-2, which has a well-characterized response up to 5 GeV. The simulations were performed using the Monte-Carlo radiation transport code Geant4, and include a complete transport from the proton beam to the measurement locations in a single calculation. An agreement between measurements and simulations is about a factor of 2 for the points where the measured radiation dose is above the background level, which is a satisfactory result for such simulations spanning many energy regimes, different physics processes and transport through several meters of shielding materials. The neutrons contributing to the radiation field emanating from the monolith were confirmed to originate from neutrons with energies above 1 MeV in the target region. The current work validates Geant4 as being well suited for deep-shielding calculations at accelerator-based spallation sources. We also extrapolate what the simulated flux levels might imply for short (several tens of meters) instruments at ESS.
[1]
Thomas Kittelmann,et al.
Polycrystalline neutron scattering for Geant4: NXSG4
,
2015,
Comput. Phys. Commun..
[2]
G. Ehlers,et al.
High energy particle background at neutron spallation sources and possible solutions
,
2014
.
[3]
Richard Hall-Wilton,et al.
Geant4 based simulations for novel neutron detector development
,
2013,
1311.1009.
[4]
G. Ehlers,et al.
The new cold neutron chopper spectrometer at the Spallation Neutron Source: design and performance.
,
2011,
The Review of scientific instruments.
[5]
S. Incerti,et al.
Geant4 developments and applications
,
2006,
IEEE Transactions on Nuclear Science.
[6]
E. Iverson,et al.
The Spallation Neutron Source (SNS) project: a fertile ground for radiation protection and shielding challenges.
,
2005,
Radiation protection dosimetry.
[7]
N. Nakao,et al.
MARS14 deep-penetration calculation for the ISIS target station shielding
,
2004
.
[8]
N. Nakao,et al.
Measurements of high energy neutrons penetrated through iron shields using the Self-TOF detector and an NE213 organic liquid scintillator
,
2002
.
[9]
E. Schachinger,et al.
The biological shield of a high-intensity spallation source: a Monte Carlo design study
,
2002
.
[10]
R. Olsher,et al.
WENDI: an improved neutron rem meter.
,
2000,
Health physics.
[11]
M. P. Guthrie,et al.
News item results from medium-energy intranuclear-cascade calculation
,
1971
.
[12]
J. Mcdonald,et al.
RADIATION PROTECTION DOSIMETRY.
,
1969
.