A Novel Offline to Online Approach to Detect Transformer Interturn Fault
暂无分享,去创建一个
Makarand S. Ballal | B. S. Umre | Hiralal Murlidhar Suryawanshi | P. A. Venikar | Prasad Arvind Venikar | H. Suryawanshi | M. Ballal | B. Umre
[1] Ibrahim El-Amin,et al. Factors that influence transformer no-load current harmonics , 2000 .
[2] K.R. Farmer,et al. Acousto-optical PD detection for transformers , 2006, IEEE Transactions on Power Delivery.
[3] S. Liu,et al. FE-Based Modeling of Single-Phase Distribution Transformers With Winding Short Circuit Faults , 2006, IEEE Transactions on Magnetics.
[4] Eddy So,et al. No-load loss measurements of power transformers under distorted supply voltage waveform conditions , 2002, CPEM 2002.
[5] P. M. Eleftherion. Partial discharge. XXI. Acoustic emission based PD source location in transformers , 1995 .
[6] Antonio J. Marques Cardoso,et al. Extended Park's vector approach-based differential protection of three-phase power transformers , 2012 .
[7] Alfonso Bachiller-Soler,et al. Inrush current mitigation in three-phase transformers with isolated neutral , 2015 .
[8] M.F. Cabanas,et al. A New Online Method Based on Leakage Flux Analysis for the Early Detection and Location of Insulating Failures in Power Transformers: Application to Remote Condition Monitoring , 2007, IEEE Transactions on Power Delivery.
[9] Yahia Baghzouz,et al. Analysis of three-phase transformer no-load characteristics , 1995 .
[10] A. Abu-Siada,et al. A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.
[11] A. Setayeshmehr,et al. Diagnosing Shorted Turns on the Windings of Power Transformers Based Upon Online FRA Using Capacitive and Inductive Couplings , 2011, IEEE Transactions on Power Delivery.
[12] Luís M R Oliveira,et al. A Permeance-Based Transformer Model and Its Application to Winding Interturn Arcing Fault Studies , 2010, IEEE Transactions on Power Delivery.
[13] A. J. Marques Cardoso,et al. Leakage Inductances Calculation for Power Transformers Interturn Fault Studies , 2015, IEEE Transactions on Power Delivery.
[14] J. Gibeault,et al. Early detection and continuous monitoring of dissolved key fault gases in transformers and shunt reactors , 1995, Proceedings:Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference.
[15] M. Heathcote. The J&P Transformer Book: A Practical Technology of the Power Transformer , 1998 .
[16] M. Duval,et al. Dissolved gas analysis: It can save your transformer , 1989, IEEE Electrical Insulation Magazine.
[17] W.H. Tang,et al. A Probabilistic Classifier for Transformer Dissolved Gas Analysis With a Particle Swarm Optimizer , 2008, IEEE Transactions on Power Delivery.
[18] L. Satish,et al. Localisation of discrete change in a transformer winding: a network-function-loci approach , 2011 .
[19] S. Liu,et al. Investigation of the harmonic behavior of three phase transformer under nonsinusoidal operation using finite element and wavelet packets , 2006, IEEE Transactions on Magnetics.
[20] A. Singh,et al. Apparatus for Online Power Transformer Winding Monitoring Using Bushing Tap Injection , 2009, IEEE Transactions on Power Delivery.
[21] E.P. Dick,et al. Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.
[22] Debangshu Dey,et al. Recent Trends in the Condition Monitoring of Transformers , 2013 .
[23] A. Abu-Siada,et al. A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.
[24] P. Purkait,et al. Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements , 2005, IEEE Transactions on Power Delivery.
[25] S. A. Khaparde,et al. Transformer Engineering: Design, Technology, and Diagnostics, Second Edition , 2012 .
[26] R. Ahshan,et al. The Development of a $d$ – $q$ Axis WPT-Based Digital Protection for Power Transformers , 2012 .
[27] Abolfazl Vahedi,et al. Numerical modelling of transformers interturn faults and characterising the faulty transformer behaviour under various faults and operating conditions , 2011 .
[28] Y.-C. Huang,et al. Condition assessment of power transformers using genetic-based neural networks , 2003 .
[29] Neil Genzlinger. A. and Q , 2006 .
[30] E. Gockenbach,et al. Asset-Management of Transformers Based on Condition Monitoring and Standard Diagnosis [Feature Article] , 2008, IEEE Electrical Insulation Magazine.
[31] S. V. Kulkarni,et al. Alternative statistical techniques for aiding SFRA diagnostics in transformers , 2012 .
[32] Ilia Voloh,et al. Detection of inter-turn fault in transformers at incipient level , 2014, 2014 International Conference on Electrical Machines (ICEM).
[33] Q. H. Wu,et al. Detection of power transformer winding deformation and variation of measurement connections using a hybrid winding model , 2012 .