Development of antibody array for simultaneous detection of foodborne pathogens.

Pathogenic bacterial contaminations present serious problems for food industry and public health. Rapid, accurate and affordable assays are needed. In this study, antibody arrays to simultaneously detect two foodborne pathogenic bacteria (Escherichia coli O157:H7 and Salmonella spp.) have been developed using chemiluminescent detecting system. Solid supports using nitrocellulose membrane and poly-l-lysine (PLL) glass slide were compared and optimized for antibody array construction. Many parameters including optimal concentrations of antibodies, blocking reagents, assay time, storage time, sensitivity and cross-reactivity were considered during optimization. This study revealed that the PLL slide was a more suitable support due to highly accurate results and the absence of non-specific background. Phosphate-buffered saline (PBS, pH 7.2) and 3% skim milk in PBS buffer were optimal spotting and blocking reagents, respectively. With the same sensitivity for bacterial detection as in a conventional ELISA (10(5)-10(6)CFU/ml for the E. coli O157:H7 and 10(6)-10(7)CFU/ml for Salmonella detections), this antibody array has advantages of a much shorter assay time of 1h and much lower required amounts of antibodies. Moreover, there was no cross-reactivity in the detection among bacteria tested in this study. Bacteria detection in food sample was feasible as demonstrated using bacteria-added milk.

[1]  Jie Wu,et al.  A disposable two-throughput electrochemical immunosensor chip for simultaneous multianalyte determination of tumor markers. , 2007, Biosensors & bioelectronics.

[2]  R. O'Kennedy,et al.  Advances in biosensors for detection of pathogens in food and water , 2003 .

[3]  Lisa C Shriver-Lake,et al.  Multiplexed measurement of serum antibodies using an array biosensor. , 2006, Biosensors & bioelectronics.

[4]  Feng Yan,et al.  A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers. , 2007, Clinical chemistry.

[5]  H. Ju,et al.  Channel-resolved multianalyte immunosensing system for flow-through chemiluminescent detection of alpha-fetoprotein and carcinoembryonic antigen. , 2008, Biosensors & bioelectronics.

[6]  James M. Jay,et al.  Modern food microbiology , 1970 .

[7]  Amanda M White,et al.  Evaluation of surface chemistries for antibody microarrays. , 2007, Analytical biochemistry.

[8]  Keun-Sung Kim,et al.  Production of monoclonal antibody against Listeria monocytogenes and its application to immunochromatography strip test. , 2007, Journal of microbiology and biotechnology.

[9]  P. Luciw,et al.  Simultaneous Detection of Antibodies to Six Nonhuman-Primate Viruses by Multiplex Microbead Immunoassay , 2006, Clinical and Vaccine Immunology.

[10]  H. Ju,et al.  A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay. , 2008, Biosensors & bioelectronics.

[11]  Microimmunoassay Using a Protein Chip: Optimizing Conditions for Protein Immobilization , 2002, Clinical and Vaccine Immunology.

[12]  S. McClintock,et al.  Comparison of antibody array substrates and the use of glycerol to normalize spot morphology. , 2005, Experimental and molecular pathology.

[13]  A. Gehring,et al.  An antibody microarray, in multiwell plate format, for multiplex screening of foodborne pathogenic bacteria and biomolecules , 2008, Analytical and bioanalytical chemistry.

[14]  V. Radke The need for partnerships for food safety. , 2006, Journal of environmental health.

[15]  Peter Gerner-Smidt,et al.  Recent developments and future prospects in subtyping of foodborne bacterial pathogens. , 2007, Future microbiology.

[16]  P. Peluso,et al.  Optimizing antibody immobilization strategies for the construction of protein microarrays. , 2003, Analytical biochemistry.

[17]  Jin-hai Tang,et al.  Channel and substrate zone two-dimensional resolution for chemiluminescent multiplex immunoassay. , 2007, Analytical chemistry.

[18]  Y. Chuang,et al.  Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7. , 2008, Biosensors & bioelectronics.

[19]  Jirí Homola,et al.  Quantitative and simultaneous detection of four foodborne bacterial pathogens with a multi-channel SPR sensor. , 2006, Biosensors & bioelectronics.

[20]  S. S. Deshpande Enzyme Immunoassays: From Concept to Product Development , 1996 .

[21]  E. Alocilja,et al.  A conductometric biosensor for biosecurity. , 2003, Biosensors & bioelectronics.

[22]  H. Ju,et al.  Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers. , 2006, Analytical chemistry.

[23]  L. McCaig,et al.  Food-related illness and death in the United States. , 1999, Emerging infectious diseases.

[24]  Ralf Ehricht,et al.  A simple and rapid protein array based method for the simultaneous detection of biowarfare agents , 2006, Proteomics.