B0 and B1‐insensitive uniform T1‐weighting for quantitative, first‐pass myocardial perfusion magnetic resonance imaging

Myocardial perfusion can be estimated, in principle, from first‐pass MR images by converting the T1‐weighted signal–time curves to contrast agent concentration–time curves. Typically, T1 weighting is achieved by saturating the magnetization with a nonselective radiofrequency (RF) pulse prior to the imaging sequence. The accuracy of the perfusion estimate derived from the single‐point T1‐weighted signal depends on the initial residual longitudinal magnetization (RLM) produced by the saturation pulse. In this study we demonstrate that single‐shot, echo‐planar imaging can be used to show initial RLM resulting from incomplete saturation due to static magnetic field and RF field inhomogeneities in the heart at 1.5 T. Three saturation pulses, single, composite simple, and composite B1‐insensitive rotation (BIR‐4) were evaluated in phantom and cardiac experiments. The RLM image was calculated by normalizing the saturated image by a proton‐density‐weighted image. Mean RLM produced by the three saturation pulses was significantly different in noncontrast cardiac imaging (RLMsingle = 0.108 ± 0.078; RLMcomposite = 0.051 ± 0.052; RLMBIR‐4 = 0.011 ± 0.009; P < 0.001; n = 20). Using a BIR‐4 pulse to perform saturation of magnetization seems promising for improving the effectiveness and uniformity of T1 weighting for first‐pass perfusion imaging. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

[1]  Michael Jerosch-Herold,et al.  Magnetic resonance imaging of myocardial contrast enhancement with MS‐325 and its relation to myocardial blood flow and the perfusion reserve , 2003, Journal of magnetic resonance imaging : JMRI.

[2]  R. Gupta,et al.  Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI , 1993, IEEE Trans. Medical Imaging.

[3]  Ray Freeman,et al.  NMR population inversion using a composite pulse , 1979 .

[4]  G. Bodenhausen,et al.  Principles of nuclear magnetic resonance in one and two dimensions , 1987 .

[5]  P. Narayana,et al.  Effect of Radio Frequency Inhomogeneity Correction on the Reproducibility of Intra‐Cranial Volumes Using MR Image Data , 1995, Magnetic resonance in medicine.

[6]  T. Parrish,et al.  3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4. , 1990, Investigative radiology.

[7]  R. Edelman,et al.  First-pass cardiac perfusion: evaluation with ultrafast MR imaging. , 1990, Radiology.

[8]  M. Jerosch-Herold,et al.  Myocardial blood flow quantification with MRI by model-independent deconvolution. , 2002, Medical physics.

[9]  Robert V Mulkern,et al.  Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0T , 2003, Journal of magnetic resonance imaging : JMRI.

[10]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[11]  H. Carr,et al.  The Principles of Nuclear Magnetism , 1961 .

[12]  E R McVeigh,et al.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T , 1998, Magnetic resonance in medicine.

[13]  R. Wilson,et al.  Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging. , 1997, Radiology.

[14]  Albert Macovski,et al.  Coronary Angiography with Magnetization‐Prepared T2 Contrast , 1995, Magnetic resonance in medicine.

[15]  K Uğurbil,et al.  Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation , 1995, Magnetic resonance in medicine.

[16]  S. Arridge,et al.  Sources of intensity nonuniformity in spin echo images at 1.5 T , 1994, Magnetic resonance in medicine.

[17]  P Wach,et al.  Imaging of the active B1 field in vivo , 1996, Magnetic resonance in medicine.

[18]  U Klose,et al.  Mapping of the radio frequency magnetic field with a MR snapshot FLASH technique. , 1992, Medical physics.

[19]  E Fleck,et al.  New developments in non-invasive cardiac imaging: critical assessment of the clinical role of cardiac magnetic resonance imaging. , 1998, European heart journal.

[20]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[21]  M A Horsfield,et al.  A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging. , 1999, Journal of the American College of Cardiology.

[22]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.